I'll pass your usage scenario along to the hpsum and SPP groups
Re: Latest Proliant Service Pack does not support Windows Server Core installations?
Re: Latest Proliant Service Pack does not support Windows Server Core installations?
I would be really gratefull :)
Best Regards,
Re: Proliant Microserver TCPIP issue
This is a duplicate, please reply in the following topic:
http://h30499.www3.hp.com/t5/ProLiant-Servers-Netservers/Proliant-Microserver-TCIP-issue/m-p/6383189
cannot replace failed frive
I am facing the following situation were rebuild is not starting. what should I do?
the unassigned drive (2I:1:1) is in the same slot as the failed drive (1I:1:1) but with different name.
starlnx1:~# hpacucli ctrl slot=1 show config detail
Smart Array P400 in Slot 1
Bus Interface: PCI
Slot: 1
Serial Number: PA2240J9SU038D
Cache Serial Number: PA82C0D9STZ5QY
RAID 6 (ADG) Status: Enabled
Controller Status: OK
Hardware Revision: B
Firmware Version: 7.22
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 15 secs
Surface Scan Mode: Idle
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: Temporarily Disabled
Cache Status Details: Cache disabled; requires reboot to enable cache.
Cache Ratio: 25% Read / 75% Write
Drive Write Cache: Disabled
Total Cache Size: 256 MB
Total Cache Memory Available: 208 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Batteries
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: False
Array: A
Interface Type: SAS
Unused Space: 0 MB
Status: Failed Physical Drive
Array Type: Data
One of the drives on this array have failed or has been removed.
Logical Drive: 1
Size: 279.4 GB
Fault Tolerance: RAID 1
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 128 KB
Full Stripe Size: 128 KB
Status: Interim Recovery Mode
Caching: Enabled
Unique Identifier: 600508B1001030364130433244300500
Disk Name: /dev/cciss/c0d0
Mount Points: / 14.0 GB, none 5.6 GB, /VM 149.0 GB, /NETWORK 110.8 GB
OS Status: LOCKED
Logical Drive Label: A00008105001438006A0C2D062A9
Mirror Group 0:
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 0 MB, Failed)
Mirror Group 1:
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 300 GB, OK)
Drive Type: Data
physicaldrive 1I:1:1
Port: 1I
Box: 1
Bay: 1
Status: Failed
Last Failure Reason: No failure
Drive Type: Data Drive
Interface Type: SAS
Size: 0 MB
physicaldrive 2I:1:2
Port: 2I
Box: 1
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD9
Serial Number: KLHTETKF
Model: HP EG0300FBVFL
Current Temperature (C): 32
Maximum Temperature (C): 39
PHY Count: 2
PHY Transfer Rate: Unknown, Unknown
unassigned
physicaldrive 2I:1:1
Port: 2I
Box: 1
Bay: 1
Status: OK
Drive Type: Unassigned Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10500
Firmware Revision: HPD0
Serial Number: Z320A184FTM91349
Model: HP EG0300FCSPH
Current Temperature (C): 31
Maximum Temperature (C): 35
PHY Count: 2
PHY Transfer Rate: Unknown, Unknown
Re: cannot replace failed frive
Hello :)
You need to assign physicaldrive 2I:1:1 as spare for that array
Re: cannot replace failed frive
I can't:
starlnx1:~# hpacucli ctrl slot=1 array A add spares=2I:1:1
Error: This operation is not supported with the current configuration. Use the
"show" command on devices to show additional details about the
configuration.
Reason: Array is transforming
Re: cannot replace failed frive
Backup server data
Shutdown server
Replace failed drive with unassigned drive
Power on server and observe dialogs and prompt from P400 controller
(there might be a rebuild/repair ... can't remember exactly for P400 but here:
Re: cannot replace failed frive
I will try that. I have tryied so many things on this array that I am not sure if I have already done it.
I will let you know ...
regards
Kostis.
Re: DL120 G6 LO100 Virtual KVM/Media Error Application Error Security Exception
Hi...
I resolved this problem in the java configuration
try
A.- Start --> Control panel --> Java
B.- In the "Java Control Panel" --> "Security" tab and choose "medium"
C.- Clic "OK" and restart browser.
Regards
replace of disks in RAID5
On the DL380 G5 server the disk No. 8 in offline failed
The controler Smart Array P400, RAID5 from 8 disks, isn't present hot spare
I replaced a disk 8 on hot, I pulled out a disk and I inserted new without switching off the server
I passed rebuild the massif successfully
In Array Configuration Utility of mistakes any isn't present, the status at all OK
In diagnostics of HP System Management shows an error of reading/record on this disk
why? what I did wrong?
is possible to fix this error?
Re: Provisioning - Windows could not create a partition on disk 0
Thanks, that's exactly what it was. Great tool, but only as good as the documentation that comes with it
hp DL380 G5 network config.
Hi All,
After re-installing ESXi 5.X, I am able to configure only one NIC via network management screen.
We have 4 NICs, where can I configure the rest for static IP?
Thanks in advance.
Best Regards,
Re: replace of disks in RAID5
You may try updating the firmware of the firmware. You may download the firmware from the following link:
Regards,
Vijayasarathy
Re: 1783 smart controller E200i
Re: Starting DL360 G6 without fully redundant fan setup
Ensure that fans are populated at a minimum in fan1 and fan 2 and remove all components such as all expansion cards, riser cards and check if the server powers on. If so, then add one component at a time and power on the server to isolate component that could cause thermal issues.
Regards,
Vijayasarathy
Re: Starting DL360 G6 without fully redundant fan setup
Hi,
the server is not at my site, but in the datacenter. They tried to check which of the fans is broken and changed the slots of the different fan modules. It looks like something is broken with fan slot 4 and at the moment I think the fan element in slot 1 has a problem. Do I need to replace the systems mainboard when fan slot 4 is reporting an error with every fan module, even with one which works in another slot?
I do have a replacement server which is on his way to the datacenter at the moment. Therefore I need to wait until they send me the broken server back. Then I'll provide further information.
regards,
Andi
SPP 2014.02.0 on Ubuntu 10.04.4 LTS
Hi,
I'm trying to run hpsum from SPP 2014.02 on a DL360 G7 running Ubuntu 10.04.4 LTS x64.
When I run swpackages/hpsum this error is showed:
hpsum: 35: Syntax error: "(" unexpected (expecting "fi")
so I try to run directly /swpackages/x64/hpsum_bin_x64
and it shows:
hpsum_service_x64 started successfully on port 63001 and ssl port 63002.
Error: cannot launch browser.
The error about the browser is correct because I have no browser installed on system.
So using my pc browser I connect to https:/ip:63002 and I can run HP Smart Update Manager 6.2.0, but after inventory of baseline is done correctly, I receive "Inventory error" on "inventory of node" section.
Can someone please help me?
Thanks
Need to convert Raid 1+0 with spare to Raid 5
I need to convert Raid 1+0 with spare to Raid 5 is it can be done with out data loss.
server space is near filledand have 80 GB free space in that logical drive(300)
I have HP DL385G6 server with smart array P410 with two SAS array.
array a is raid 1+0 with each 72 GB disk.
No need to change.
And Array B with Raid 1+0 with a spare disk.
Two 300 GB hard disk and one spare where the spare is failed now.
Please guide whether I may able to replace the failed spare disk with new one and delete the spare configuration and create Raid 5 configuration for this given below scenario without any Data loss
or We need to for look for a free slot.?
Re: cannot replace failed frive
No, it didn't work
I am going to start a new thread.
Smart Array get confused
After moving the drives between P410i and P400 hpacucli reports:
starlnx1:~# hpacucli ctrl slot=1 show config detail
Smart Array P400 in Slot 1
Bus Interface: PCI
Slot: 1
Serial Number: PA2240J9SU038D
Cache Serial Number: PA82C0D9STZ5QY
RAID 6 (ADG) Status: Enabled
Controller Status: OK
Hardware Revision: B
Firmware Version: 7.22
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 15 secs
Surface Scan Mode: Idle
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: Temporarily Disabled
Cache Status Details: Cache disabled; requires reboot to enable cache.
Cache Ratio: 25% Read / 75% Write
Drive Write Cache: Disabled
Total Cache Size: 256 MB
Total Cache Memory Available: 208 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Batteries
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: False
Array: A
Interface Type: SAS
Unused Space: 0 MB
Status: Failed Physical Drive
Array Type: Data
One of the drives on this array have failed or has been removed.
Logical Drive: 1
Size: 279.4 GB
Fault Tolerance: RAID 1
Heads: 255
Sectors Per Track: 32
Cylinders: 65535
Strip Size: 128 KB
Full Stripe Size: 128 KB
Status: Interim Recovery Mode
Caching: Enabled
Unique Identifier: 600508B1001030364130433244300500
Disk Name: /dev/cciss/c0d0
Mount Points: / 14.0 GB, none 5.6 GB, /VM 149.0 GB, /NETWORK 110.8 GB
OS Status: LOCKED
Logical Drive Label: A00008105001438006A0C2D062A9
Mirror Group 0:
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 0 MB, Failed)
Mirror Group 1:
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 300 GB, OK)
Drive Type: Data
physicaldrive 1I:1:1
Port: 1I
Box: 1
Bay: 1
Status: Failed
Last Failure Reason: No failure
Drive Type: Data Drive
Interface Type: SAS
Size: 0 MB
physicaldrive 2I:1:2
Port: 2I
Box: 1
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10000
Firmware Revision: HPD9
Serial Number: KLHTETKF
Model: HP EG0300FBVFL
Current Temperature (C): 32
Maximum Temperature (C): 39
PHY Count: 2
PHY Transfer Rate: Unknown, Unknown
unassigned
physicaldrive 2I:1:1
Port: 2I
Box: 1
Bay: 1
Status: OK
Drive Type: Unassigned Drive
Interface Type: SAS
Size: 300 GB
Rotational Speed: 10500
Firmware Revision: HPD0
Serial Number: Z320A184FTM91349
Model: HP EG0300FCSPH
Current Temperature (C): 31
Maximum Temperature (C): 35
PHY Count: 2
PHY Transfer Rate: Unknown, Unknown
The unassigned drive (2I:1:1) is in the same slot as the failed drive (1I:1:1) but with different name.
rebuild is not starting. what should I do?