Re: ProLiant DL380 G7 - Lost NICs after Driver-Update

Hi ErikD,

Itried thesuggestionand it works.

Configuration is:

4 onboard NICs, one active

1 Fibrechannel-NIC active

this 2 NICs teamed with HP-Network-Configuration-Tool. (Fibre active, onboard standby)

First i patched the active onboard-NIC with "driver-update" from the device-manager and reboot the Server.

This works fine. Than i patched the 3 inactive NICs. No reboot needed.

Now i changed the device-order in the Teaming to onboard active, fibre standby.

i patched the fibre-nic. This was OK too. I changed the device-order in the teaming back to active fibre.

At last i updated the teaming-Software with cp021816.exe to version 10.85.00.0

The server works well. at last i finally reboot the system and....

hooray, it works well.

it seems that the setup of cp021772.exe is the prolem, not the driver himself.

Thank you very much for the support

greetings Ralf

Sorry for my bad english ;)

 