Re: Latest Proliant Service Pack does not support Windows Server Core...
I'll pass your usage scenario along to the hpsum and SPP groups
View ArticleRe: Latest Proliant Service Pack does not support Windows Server Core...
I would be really gratefull :) Best Regards,
View ArticleRe: Proliant Microserver TCPIP issue
This is a duplicate, please reply in the following topic:http://h30499.www3.hp.com/t5/ProLiant-Servers-Netservers/Proliant-Microserver-TCIP-issue/m-p/6383189
View Articlecannot replace failed frive
I am facing the following situation were rebuild is not starting. what should I do?the unassigned drive (2I:1:1) is in the same slot as the failed drive (1I:1:1) but with different name. starlnx1:~#...
View ArticleRe: cannot replace failed frive
Hello :) You need to assign physicaldrive 2I:1:1 as spare for that array
View ArticleRe: cannot replace failed frive
I can't: starlnx1:~# hpacucli ctrl slot=1 array A add spares=2I:1:1Error: This operation is not supported with the current configuration. Use the"show" command on devices to show additional details...
View ArticleRe: cannot replace failed frive
Backup server data Shutdown server Replace failed drive with unassigned drive Power on server and observe dialogs and prompt from P400 controller (there might be a rebuild/repair ... can't remember...
View ArticleRe: cannot replace failed frive
I will try that. I have tryied so many things on this array that I am not sure if I have already done it.I will let you know ...regardsKostis.
View ArticleRe: DL120 G6 LO100 Virtual KVM/Media Error Application Error Security Exception
Hi...I resolved this problem in the java configurationtry A.- Start --> Control panel --> JavaB.- In the "Java Control Panel" --> "Security" tab and choose "medium"C.- Clic "OK" and restart...
View Articlereplace of disks in RAID5
On the DL380 G5 server the disk No. 8 in offline failedThe controler Smart Array P400, RAID5 from 8 disks, isn't present hot spareI replaced a disk 8 on hot, I pulled out a disk and I inserted new...
View ArticleRe: Provisioning - Windows could not create a partition on disk 0
Thanks, that's exactly what it was. Great tool, but only as good as the documentation that comes with it
View Articlehp DL380 G5 network config.
Hi All, After re-installing ESXi 5.X, I am able to configure only one NIC via network management screen.We have 4 NICs, where can I configure the rest for static IP? Thanks in advance. Best Regards,
View ArticleRe: replace of disks in RAID5
You may try updating the firmware of the firmware. You may download the firmware from the following link:...
View ArticleRe: Starting DL360 G6 without fully redundant fan setup
Ensure that fans are populated at a minimum in fan1 and fan 2 and remove all components such as all expansion cards, riser cards and check if the server powers on. If so, then add one component at a...
View ArticleRe: Starting DL360 G6 without fully redundant fan setup
Hi, the server is not at my site, but in the datacenter. They tried to check which of the fans is broken and changed the slots of the different fan modules. It looks like something is broken with fan...
View ArticleSPP 2014.02.0 on Ubuntu 10.04.4 LTS
Hi,I'm trying to run hpsum from SPP 2014.02 on a DL360 G7 running Ubuntu 10.04.4 LTS x64.When I run swpackages/hpsum this error is showed:hpsum: 35: Syntax error: "(" unexpected (expecting "fi") so I...
View ArticleNeed to convert Raid 1+0 with spare to Raid 5
I need to convert Raid 1+0 with spare to Raid 5 is it can be done with out data loss.server space is near filledand have 80 GB free space in that logical drive(300) I have HP DL385G6 server with smart...
View ArticleSmart Array get confused
After moving the drives between P410i and P400 hpacucli reports: starlnx1:~# hpacucli ctrl slot=1 show config detailSmart Array P400 in Slot 1Bus Interface: PCISlot: 1Serial Number: PA2240J9SU038DCache...
View Article