Re: Network bridging in Windows Server 2012 killing HP Ethernet Adapter ?

Cool, I'm glad it worked.  If the switch had shut them down or something if it saw a loop, fixing the server configuration and giving the switch time to clear the STP or whatever else it did was...

View Article


Re: DL380e G8 - fan noise and inlet temperature

Also, I think in another thread, someone mentioned that using non-HP branded drives could impact the monitoring of temperatures in certain zones. Especially in the G8 models where HP actually went out...

View Article


ML110 G7 USB boot

Hi guys, Got an ML110G7 with the current firmware as of 12/05/2014. There's a 2.5" USB HDD connected to the system (used for backups). It's bizarre, When the system reboots, it will randomly just sit...

View Article

Re: Dual Booting Server

Hi Berkleigh, Unfortunately I can't help you - haven't done it yet.  Client is delaying the job for some reason however at this stage we are looking to back everything up, wipe 2003 and fresh install...

View Article

Re: Network bridging in Windows Server 2012 killing HP Ethernet Adapter ?

Yes, that was the case. Thank you for the sharing and the explanation for the behavior of server Network teaming.

View Article


Re: Proliant ML350e Gen8 don't boot

Hi Try to upgrade the firmware of the server using latest SPP and then try. http://h17007.www1.hp.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx  

View Article

Re: Is SPP Version 2014.02.0(B) suitable for dl380p G8

The server is supported, get it from here: http://www.hp.com/go/spp

View Article

Re: Proliant ML350e Gen8 don't boot

You should try to run the Array Configuration Utily (smart storage administrator) from the SPP directly and check the smart array controller and configure logical drives. Consider to udate intelligent...

View Article


Re: Installing Windows server W2K12 on a Proliant DL380 G7

Thanks for your reply.Even after taking out the P212, I would still have the problem.Thanks for sharing your experience. Eric

View Article


Re: 2.5 inch ssd in ml350 g6 with 3.5 inch bays

http://www.kingston.com/us/memory/search/?partid=SNA-DC2/35

View Article

HP dl380 Gen7 with Smart Array 421

Hello, we have a HP dl380 Gen7 with Smart Array 410.The server has 12 cores + HT and 144 GB RAM, is a good server and we don't need upgrade to a Gen8.We want add a new RAID card to improve the...

View Article

No DVD after OS install.

Hi, We have a DL380 Gen8p server and installing the Linux OS 6.2 from DVD is fine, after the rebooting the server we can not mount the DVD drive only USB drives appear to work. Tried to look for a...

View Article

Re: HP dl380 Gen7 with Smart Array 421

This smart array is not listed in the servers quickspecs and hence not supported. I guess the reason is the server has pci-e gen2 slots only, the HBA is Gen3. I think it will work (downshift), but a...

View Article


DL585 G2 removal of psu2 fans

Hey, i'm having some problems with noise and i was thinking, is it possible to remove the 2 fans blowing on the psu2, which is not in use nor connected to power.I don't need the psu redundancy and...

View Article

Re: few questions about ProLiant DL360 G7

The array battery missing wouldn't keep it from booting up. It would still boot and then give some kind of error or message when the array controller does it's check.The DL360 G7 has 3 memory channels...

View Article


Re: ML370 G3 Redundant Fan Failure

Hello, In a nutshell, I have a ML370 with the redunant fan issue.  I would like to replace the motherboard but I have a quick question re: model number: The model number of the board in the server at...

View Article

Re: Proliant ML370 => Fan problem

Hello, sorry to drag-up an ancient thread! Do you have a part number or a link to the opto-couplers you used please?I just need to keep this G3 going for a few more months!Al

View Article


Re: ML370 G3 Redundant Fan Failure

I think I may have just discovered the answer... the two boards have a different FSB speeds 400 / 533 as explained in this post:http://tinyurl.com/lruf95nI understand the 316864-001 is the newer board,...

View Article

Advice for avoiding configuration errors when swapping System Board on an...

Hi, Just a few months before retirement, a ML370 G3 has developed the redundant fan issue and periodically shuts down due to fan #3 failing (even though the fan has been swapped / is known to be good)....

View Article

Re: ML350 G5 server - Smart Array E200i Firmware Update

The latest version is 1.86....