Quantcast
Channel: All ProLiant Servers (ML,DL,SL) posts
Browsing all 30225 articles
Browse latest View live

Re: Installing CentOS 6.3 to DL360e can't load driver for smart array controller

Well, apparently the driver is that specific.  I just found this HP document.  It explains that they don't provide a driver for CentOS.  This really bites.  :(

View Article


Re: Query HDD model/firmware from script - Windows

I'm not sure how hpacucli runs under Windows.  All of my servers are RHEL.  In my script I use: # Determined the slot number previously and set that to SLOT hpacucli ctrl slot=${SLOT} pd all show...

View Article


Re: DL380 G8 fans.

Where is the sensor 30-PCI 2 located?It shows pretty High temp all the time, around 75-78℃ on one server and 84-85 on another. Is it normal?

View Article

How to get the mirror working again without losing any data?

Hello Guys, We are having an issue with our Proliant HP DL360 server. One of its logical drives is not mirroring (see attached ADU report). This issue started when we tried to upgrade these 2x72 GB...

View Article

Re: Installing CentOS 6.3 to DL360e can't load driver for smart array controller

Hello BradV, Even if it's not supported by HP, I'm pretty sure will work and can be installed.  Follow the details in this HP Documetn to do it using the RHEL driver:...

View Article


Re: New 1Gb Broadcom Multifunction Win64 driver (7.8.6.0) is buggy

do you manage to get it working at 1 gb ?

View Article

DL180 G6 doesn't detect SATA drives

I have a DL180 G6 with a Smart Array P410 and it won't detect any SATA drives at all but it will detect and work with SAS just fine. I can't figure it out. I have two other servers with the exact...

View Article

New G8 User

I ordered 5 DL385 G8 servers to setup a network.  I am now running 3 in a cluster and have the network up and going.  What do I need to do to start taking advantage of the new ilo in these g8 servers?...

View Article


Disk performance on HP Proliant

On my HP Proliant bl 410 box I am seeing a wierd performance behaviour. Could somebody help me understand what might be wrong? OS is RHEL 6.4 [root@pprfcgtest01 ~]# dd if=/dev/zero of=/dev/sdb1 bs=4096...

View Article


Re: Installing CentOS 6.3 to DL360e can't load driver for smart array controller

I just verified on a system with a B120i. hpvsa-1.2.44-4.rhel6u3.x86_64.dd loads fine with Centos 6.3. Are you sure your using 6.3 and not a different release version? All I did was gunzip the image...

View Article

HP ML 370 G5 additional processor

I need to upgrade my server ML 370 G5 with an additional processor, my question to add another processor, I have to add an additional power source for this new processor.regards, thank youjose flowers 

View Article

Re: Query HDD model/firmware from script - Windows

The syntax under windows is pretty much identical: hpacucli  ctrl all show config detail

View Article

Re: ML110 G5 servers catch on fire

Well I'm pleased to report that once we'd made contact with Robert Nweke at HP then things moved along and they agreed to replace the server. Now have a suitable replacement, and so I'd like to...

View Article


Re: iLO3 HP Lights Out Configuration Utility - System.Xml.XmlException

I'm now getting this error after updating manually to 1.32 (11 Nov 2013). Was working before I updated. Guessing it's a firmware release issue that needs to be fixed?

View Article

Re: DL380 G7 blue screen : NMI

Hello, Finally I managed to solve it, it was creep corrosion on both the 1GB FBWC cache and the additional SC11XE card plugged on the pci express. Changed the cache, changed the SC11XE for a new card...

View Article


Re: iLO3 HP Lights Out Configuration Utility - System.Xml.XmlException

Solution: downgraded to 1.20. Fixed the issue

View Article

ProLiant DL380 G7 Raid 5 option

Hi Guys, Im trying to setup RAID 5 on my server but the option is not availbe from the Array Configuartion Utility... see attached For some reason two smart array controllers are present is this...

View Article


HP ProLiant DL320 G6 Server - Capacity of SATA Drives Not Recognized

Hi guys :-) I hope somebody here can help. I'm actually a home/non commercial user and I've bought a' HP ProLiant DL320 G6 Server' to basically 'play' and learn how to configure/deploy as I'm hoping to...

View Article

Cannot install Windows Server 2012 via Intelligent Provisioning (ProLiant ML...

Hi all.I have a ProLiant ML380 server with no OS installed. I'd like to install Windows 2012 180-days trial.I downloaded the ISO image from Microsoft website and recorded it onto a DVD.After booting to...

View Article

Cannot install Firmware for HP EF0600FARNA harddisk

Hello, i have a server proliant ml350 g6 with hp array 410i.the smh reports an error with the firmware of my harddisk. disk1: HP EF0600FARNA Firmware: HPD2disk2: HP EF0600FATFF Firmware: HPD2 When I...

View Article
Browsing all 30225 articles