Quantcast
Channel: All ProLiant Servers (ML,DL,SL) posts
Viewing all articles
Browse latest Browse all 30225

Re: Controller not connected and i have the error - 226-Power fault detected – Embedded storage cont

$
0
0

Hi

In rare instances some of the HP ProLiant DL360p Gen8 Servers may display the following error on startup:

"226 Power fault detected - embedded storage controller, Action: re-seat storage controller if removable, otherwise contact support"

Perform the following steps to resolve the issue:

1. If condition permits and FBWC is installed in the embedded controller which is Smart Array P420i Controller, re-seat the FBWC.

2. Boot the server and check for the startup messages.

3. If the FBWC is not installed or the error message continue to show upon system startup, replace the System Board.

This issue should resolved by replacing the system board.