Re: Proliant DL360 G7 memory upgrade
because I haven't any idea about the DIMM installed on your server (HP or not HP), and how the DIMM are populated, I give you this link in order to found all the option that you can do with 40GB of...
View ArticleRe: hps report
One of the first places that I'll look after extracting it is the msinfo.nfo file. It consolidates alot of info that the other files list individually.
View ArticleRe: Smart Storage Administrator and Hyper-V 2012 R2 Core
I tried Internet Explorer 10 and Mozilla Firefox 24.0IE Show Sertificate Error
View Articlecomaptiable network cards for ml350 g5
Hi All I have a ML350 G5 server and i need ti install another network card. Does anyone know if the TP Linl TG 3269 Gigabit pci will do the job. the other alternative is to buy one from USA and wait a...
View ArticleRe: ProLiant DL380 G6 Smart Array P410i configuration Problem
Morning I’m having the same problem in one of my branches, but had the same problem at our head office and I just replaced the Smart Array battery and all the error was gone, so maybe try to replace...
View ArticleRe: Smart Storage Administrator and Hyper-V 2012 R2 Core
So if the issue is related to certification error, please send us a print screen for this error :)
View ArticleRe: comaptiable network cards for ml350 g5
for this card :http://www.tp-link.com/en/products/details/?categoryid=&model=TG-3269#spec you can install it on your server because it's a PCI compatible Hardware but you must verify with OS...
View ArticleRe: Proliant ML350 G5 Lights code
it will be great if you send us a screenshoot, wich OS is installed on this server?
View ArticleRe: Smart Storage Administrator and Hyper-V 2012 R2 Core
I think this issue is not certification error. If i write Full Domain name instead ip address, sertification error disappears, but page still blank.
View ArticleRe: Proliant ML350 G5 Lights code
I have 2 pics for now. I think it is just the PSU, because its green led is down. But the internal LED 7 or 8 is amber.
View ArticleRe: Proliant ML350 G5 Lights code
I know we are no here to protest. But I live in Rio de Janeiro, and there is no authorized reseller here to sell this PSU for me.I could find for about USD 400.00 each PSU waiting a week to receive...
View ArticleRe: Proliant ML350 G5 Lights code
First I would suspect the fans ... ;-)The server looks like a vacuum cleaner.Try to connect to the ILO, you maybe get some more status information from there.
View ArticleRe: Proliant ML350 G5 Lights code
I have changed both CPU fans to news. I have put the old one and the problem remains...
View ArticleRe: Proliant ML350 G5 Lights code
How about the ILO-2 connection? Could you tell more details about the system LEDs? BTW, a bad CPU or systemboard may look the same like your server now. You may try with a single CPU, minimum RAM,...
View ArticleRe: Proliant ML350 G5 Lights code
How can I try this ILO-2 connection? There is a led number 7 or 8 in amber color.Below the memories there is a sys fan plug. On the left side of this fan plug, there is a "pool" of 6 (I gess) leds. The...
View ArticleRe: Proliant ML350 G5 Lights code
A new PSU is comming in 3 or 4 hours. So I think when a put the new there, the system will be able to work or show me better what the problem is. In all cases, the unique amber light inside the system...
View ArticleRe: Proliant ML350 G5 Lights code
If you don't have ILO configured, plug in a LAN cable into the ILO port. DHCP is enabled, the credentials are written on the sticker.If you set the System maintenance switch DIP switch 1 to ON, you can...
View ArticleArray Accelerator Battery Charge Low - Error: 94 - HP DL 380 G5
Hi Guys,I found this error Post Error - Message: 1794-Drive Array - Array Accelerator Battery Charge Low - Error: 94 in diagnostic utility on a server HP DL 380 G5.The server automatically shutdown.The...
View ArticleRe: Array Accelerator Battery Charge Low - Error: 94 - HP DL 380 G5
The link you reference is firmware for disk drives, not the controller. You want to update the storage controller firmware. With the error your showing, you probably need to repalce the battery module...
View ArticleRe: Array Accelerator Battery Charge Low - Error: 94 - HP DL 380 G5
ok next week I will search the battery (I haven't seen it before) over the controller.But the server turns off... what could it be?In the hp diagnostic tool I see only this error. Raid is good and the...
View Article