Re: hp proliant dl80 - replacing cache memory module with battery.
Hi, Cache replacement should not cause any data loss however given the fact there is one drive failure and another drive which has no LED we would again recommend you to backup the data first. The AHS...
View ArticleRe: DL380p gen8 ILO4 firmware loading issue
HiPlease find the steps to update System ROM –BIOS and iLO 4 Firmware through iLO web console.1. Update System ROM –BIOS firmware.Type: BIOS (Entitlement Required) - System ROMVersion: 2019.05.24(12...
View ArticleML350 G6 power plugged no Led
Hi,i've been facing this issue after powering off the server, when i plugged the power cord back no power on the board no Leds at all the power supply fans are working but no led, so i have tried to...
View ArticleHP Proliant ML310e Gen8 V2. Early System Initialisation.
HI, First post here. My background was technical (once). but not for a umber of years. Have been given an old HP Proliant ML310e Gen8 V2 server. Upon startup it goes through the Early System...
View ArticleML150 G6 Processor upgrade and voltage problem
Ok, for starters I am no expert and nor will I ever claim to be, more like at home level hobbyist... I took 2 years of the Aries Computer Certification class back in high school in 99-00 so I have a...
View ArticleRe: ML150 G6 Processor upgrade and voltage problem
It's been some time since I've touched a system with the LO-100i BMC instead of iLO, so I can't recall what kind of logs it saves, but I'd start by checking the system logs
View ArticleRe: HP DL360 G7 - Need Help/Advice with Sensors Failure
Hello This should be some issue with temperature sensor. Please check IML. Check with minimum hardware configuration.If the issue remains unresolved, then log a support ticket with HPE.Thanks,
View ArticleRe: Intelligent Provisioning F10 not working Ml350 gen10
Hello, Please verify the below.Step1: Please check if the IP F10 prompt option is enabled in UEFI.Enabling or disabling the Intelligent Provisioning F10 promptUse the Intelligent Provisioning...
View ArticleHP Proliant DL360 G6 Beep sound on start and Black screen
When starting HP Proliant DL360 G6 getting beep sound and nothing on-screen only black. the checked power supply is ok Then Opened health Led and found amber color on all Rams and 1 fan Strange thing...
View ArticleDL380 BIOS
Dear colleque, We are facing an issue related to our HPE DL380 Gen9 regading to a disabled port for hard drive " logical drive disabled due to possible data loss..." , following a recomendation on...
View ArticleRe: Drives do not display in SSA on DL360 G9
Greetings!I understand that the drives are not detected on the server after replacing the Smart Storage battery on your DL360 Gen9 server. Ideally, this should not happen until some cable on the...
View ArticleRe: Drives do not display in SSA on DL360 G9
That was my first thought as wel, but I removed and reseated all cables., and even removed and reseated the array controller.
View ArticleRe: Issues preboot/Updating Firmware
HiLatest SPP version 2019.09 is not supported on G7 server, you need to use SPP version G7.1 ,You can download from following...
View ArticleRe: DL 380/G9 SSA error
Jimmy,Thanks for the advice. I was able to (finally) boot from the USB key into offline SSA. I tried about 10 times using different permutations without luck. Finally I stumbled upon the critical...
View ArticleRe: Cores to support NVMe
Hello,Please follow the below link for your reference.NVMe performance challenges expose the CPU...
View ArticleDL360 G7 410 Smart Array with PCIe SSD Fails to Boot
Hello. We have a DL360 G7 4-bay 2.5" 1U server where we are using qty-4 SSDs in the 4 bays, however we wanted to install a Marvell PCIe SSD card to run Windows 2019 Server OS. The drivers for the...
View ArticleLogical disk not visible in Windows server 2019
De second logical drive is not visable in de windws disk managamant. In the smart storage software al is looking fine.Server ML30Gen10Windows Server 2019Raid controller : Smart Array E208i-p SR Gen10...
View Article