Microserver G8 + ESXi +AHCI = some problems

Hi! I have a Microserver G8 with latest HP ESXi image stalled on SD card.And following problem was found:If in BIOS settings switch to AHCI usage - on every ESXi reboot disk disappears from ESXi server...

View Article


Re: HP ProLiant DL380 Generation

When you have a fan plugged into that location, do you actually see it spinning? If the fan spins at all, it could just be the speed sensor...If it shows an error no matter what fan you plug in there,...

View Article


Re: Microserver G8 + ESXi +AHCI = some problems

Telmah wrote:Hi! I have a Microserver G8 with latest HP ESXi image stalled on SD card.And following problem was found:If in BIOS settings switch to AHCI usage - on every ESXi reboot disk disappears...

View Article

Re: HP Proliant DL180 G6 - Smart Array P410, bay 1 error

Yeah, the amber LED on that first drive means it's failed. No lights on the 4th drive is weird... if it weren't assigned to an array or if it was a spare, that would make sense (or simply broken and...

View Article

Re: iLo on DL160se G6 stops working..

I don't have a solution for your issue, but this server has LO100 and not iLO. They are not the same BMC technology.

View Article


Re: After creating the second Array, windows doesen't boot anymore

I was curious about this... I don't see an option to change the boot volume in the smart array F8 screens (ORCA). I think maybe you have to boot from the Smartstart/SPP disc and use the full array...

View Article

Re: SFP+ labeled "not for resale" in HP 82E HBA Bundle AJ763B ??

Can you send us a screen shoot, Please?

View Article

Issue with installing HP Insight Manager WBEM Providers on DL160se G^

Trying to use HPSMH but none of the features show up.Get the following message.... "Install the latest version of HP Insight Management WBEM Providers and/or HP Insight management Agents from HP...

View Article


Re: CPU and Memory upgrade on Proliant ML350G6

BringUpMyPost

View Article


3 drivers missing after clean install of Windows Server 2012 Standard Edition

I clean installed a copy of Windows Server 2012 Standard on a DL320S and all seems well except 3 drivers show that they need to be installed....

View Article

Re: Microserver G8 + ESXi +AHCI = some problems

Yahoooo, problem was solved... Looks like once created, storage signature was assigned to RAID device, not to AHCI. So solution was very simple - just answer "Assign new signature" instead of  "Keep...

View Article

Re: After creating the second Array, windows doesen't boot anymore

waaronb wrote:I was curious about this... I don't see an option to change the boot volume in the smart array F8 screens (ORCA). I think maybe you have to boot from the Smartstart/SPP disc and use the...

View Article

Re: After creating the second Array, windows doesen't boot anymore

Yeah, I didn't see any option to do that when I tried booting a DL380 G5 from Smartstart disc either.For the original poster, you might try what Jimmy suggested, and create the new array using the ACU...

View Article


Re: 3 drivers missing after clean install of Windows Server 2012 Standard...

Try grabbing the drivers for a DL360 G6 or DL380 G6 for Server 2012. The G6 models also have the ILO2 like the G5 models do, and the ilo drivers should work.The SCSI controller is just the LSI ultra...

View Article

Re: CPU and Memory upgrade on Proliant ML350G6

As long as the new memory has the same speed (PC3-10600) then it should be fine. Be sure to visit the Quickspecs page for your ML350 G6 and pay attention to the guidelines on which slots to use to...

View Article


P420 Controller high temperature on HP DL380e Gen8 (747769-421)

Hi!Have brand new HP DL380e Gen8, uptime about 2 days.In HP smart storage administrator i see: Controller Temperature 87°CCache Module Temperature 40°CCapacitor Temperature 22°CI think controller...

View Article

HP ML110 G6 with P212 and 256 cache module

Hello, I have a ML110G6 with HP Smart Array P212 card (462828-B21)and 256 cache module(462968-B21), 3 500GB SATA disks on RAID5. I've installed ESXi 5.5 but find the disk speed quite low. ESXi is...

View Article


Re: HP ML110 G6 with P212 and 256 cache module

I had low performance on my DL160 with cache without battery (i have esxi 4.1)Adding a battery solved this problem.

View Article

Re: HP ML110 G6 with P212 and 256 cache module

And you must enable caching in bios utility, where it may be turned off

View Article

Re: HP Proliant DL180 G6 - Smart Array P410, bay 1 error

Yes, there are several advisories around all suggesting to upgrade the controller and disk drive firmware first. Get the latest SPP, create a bootable USB stick using the included tool and boot from to...

View Article