HP Compaq Proliant ML 370 G3 Server .
Dear All,Please refer attached screen shot and helpme to solved the probelm .OS : SCO Open server 6.0 2 Logical Drive1779 slot 1 Drive arrey -replcement drive(s) detected Or previously faileddrive(s)...
View ArticleRe: P410 RAID Controller Installation - Configuration on Proliant DL 160 G6
Boot Controller Order menuThe Boot Controller Order option selects which of the installed mass storage device controllers is used as the primary boot controller. The server attempts to boot the drives...
View ArticleRe: ML350e G8 v2 vs ML350p G8
the difference is in the type of processor and controller card installed and other components, I give you the QuickSpecs of each one in order to compare theme.
View ArticleRe: HP Compaq Proliant ML 370 G3 Server .
1779 Error Message1779-Slot X Drive Array - Replacement drive(s) detected OR previously failed drive(s) now operational:... ...Port Y: SCSI ID Z: Restore data from backup if replacement drive X has...
View ArticleRe: P410 RAID Controller Installation - Configuration on Proliant DL 160 G6
Thank you very much for the response. In the Boot Controller Order I am not seeing the P410. So this is screaming firmware update to me. Does that sound correct? So then here comes the really dumb...
View ArticleRe: P410 RAID Controller Installation - Configuration on Proliant DL 160 G6
Please Check if card is enabled under RBSU [BIOS]: this image is just an example PCI Device Enable/Disable menuThese options enable and disable embedded and add-in devices. Disabling devices...
View ArticleRe: HP Proliant DL180 G6 - Smart Array P410, bay 1 error
Hello Again! I've downloaded the offline ACU to further check the array and found out that there were two disk showing error notifications. Out of 12 slots... 11th one showed that its rebuilding &...
View ArticleDL380 Gen8 - Insight Manager?, Smart Update Manager? and Service Pack for...
Hi, could some one give me some info on these various bits of software... Way back when you setup a Proliant, Smartstart would install the variuos HP drivers along with Insight Manager and off you...
View ArticleHP ProLiant ML150 G6 Server hard drive problem
i have an old HP ProLiant ML150 G6 Server with windows server 2003 that has 3 disk 1 ,2 ,3 TB , irecently buy new wd 4 tb green but the problem that it sees only 1.7 tb regards P.S. This thread has...
View ArticleRe: DL380 Gen8 - Insight Manager?, Smart Update Manager? and Service Pack for...
Here you can finf the Guide Installation for HP SIM [System Insight Manager]...
View ArticleRe: HP ProLiant ML150 G6 Server hard drive problem
Whixh type of Storage Controller you have on this server? Performance model: HP Smart Array P410/256MB RAID Controller (RAID 0/1/1+0/5/5+0)Base model: HP Smart Array P410 Controller (RAID 0,1std) Zero...
View ArticleRe: DL380 G8 fans.
HP suport answered me with recomendation to move a cooler from 6 slot to first.Server became quieter!! Now i have 5 fans in 1,2,3,4,5 slots and 6 is empty.
View ArticleRe: DL380 G5 array SCSI 320 VHDCI
Hi Mark, I've been asked to connect two old U160 Arrays to a DL380-G5. I speced the 273914-B21 and relaized I need Mixed Riser Cage Option Kit (PCI-E/PCI-X) 410570-B21. Besides the SCSI cables to...
View ArticleRe: DL380 G8 fans.
I believe when I tested mine, I had all 6 FANs populated. Since the P420 card inside that storage model requires a lot of air to remain cool, I would advice you to add an extra fan for slot 6.
View ArticleRe: Help with Smart Array P410 specs and update?
scharchouf wrote:Wich OS is installed?Sorry, it's CentOS 6.4
View ArticleRe: Proliant DL360 G5 Power Supply - Home Use
The quick answer is Yes. It will auto switch between 110-120 and 220-240 volts
View ArticleRe: Help with Smart Array P410 specs and update?
hpacucli-8.70-8.0.noarch.rpm http://downloads.linux.hp.com/SDR/downloads/ProLiantSupportPack/centos/6.0/x86_64/8.72/
View ArticleRe: Help with Smart Array P410 specs and update?
quickest way to see what the current firmware version is on the P410, cat /proc/scsi/scsi You can also look in dmesg and see the firmware level and driver version when hpsa loads
View Article