Repalce HDD failed at HP BLC460 G8

$
0
0

Hi

I have failed HDD on my Server .

when i repalced HDD still failed ( degraded (predictive failure)  ) and i noticed that the HDD firemware is HPD9 and the old one was HPD7

Please check attached PIC

please support

 


How to Extend to the Max SFF Hard Drivessupported by HP Proliant DL380p Gen8

$
0
0

Good Day Experts

As stated in the below reference, the server can host 25 SFF hard drives. Do you have the official procedure to extend from 8 to 16 by removing the optical drive cage and then the procedure to extend from 16 to 25.

If there is any movie that explain the steps, please share the link, it will be more helpfull. 

 

HP ProLiant DL380p Gen8 Server - Overview

https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-c03235277

 

iLo4 don't see the storage controller P420 (DL380p Gen8)

$
0
0

Good Day Experts

We noticed in the iLo4 web interface under 'System Information' that storage information is not populated and at Device Inventory we don't have details for this Embedded Storage Controller.

Just note that server run on OS RHEL 6.5 and iLo FW 2.61

Any idea ?

Any helpful CLI commands ?

Re: DL380P Gen8 will not boot to anything but C: drive.

$
0
0

I would love to but I do not have an HPE warranty any more on this server.

Any other ideas?

 

Eric

Re: Proliant ML350p Gen8 suitable as workstation

$
0
0

Hi there, 

Please find the answers to your queries: 

1. Can Windows 7 / 10 be installed on a ML350p Gen8 ?

A. No. Please find the Support matrix : http://h17007.www1.hpe.com/us/en/enterprise/servers/supportmatrix/windows.aspx#.W_uEduhLiM8

2. What are the components of the HP Graphics card support kit? Is it more than a power cable for a Quadro? 

A. The adapter you need is NVIDIA Quadro K6000 PCI-E Graphics Adapter [730874-B21].

Please find the link which will give this info : http://partsurfer.hpe.com/Search.aspx?SearchText=730874-B21

Regards,

Shruthi (HPE Employee)

--

If you feel this was helpful please click the KUDOS! Thumbs below!

Re: iLO 4 - snmp not working

$
0
0

Hi Manuito,

To get the response temperature, PSU, etc., one need to provide the OID.

To get the OID for the MIB kit is available at https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-c04272529.

The MIBs are self explanatory and can be read in an editor and extract the required OID from MIB kit.

The syntax would be #snmpwalk -v1 -c public iLO4IP/FQDN OIDstring

You can refer the blog https://ixnfo.com/en/snmp-oid-list-for-ilo4.html for iLO4 SNMP OID list.

Disclaimer: One or more of the links above will take you outside the Hewlett-Packard Enterprise web site, HPE does not control and is not responsible for information outside of the HPE web site.


"If you feel this was helpful please click the KUDOS! Thumbs below!"

Regards,
KK

Re: SSD & HDD Positions

$
0
0

Since SAS has a point to point connection, all slots are equal.

Re: System ROMPaq Firmware for HP ProLiant DL380p Gen8 (P70) Servers

$
0
0

The "Redunandant System ROM" is for failback, if your new Firmware Version makes trouble.


Re: All 10GB NICs for DL380 Gen10 retired?

$
0
0

Must be a mistake, it is not retiered.

Re: Hard Disk Firmware cannot get updated

$
0
0

 

After reading some articles about our server hardware on the HP site, I finnally undrstand what does Zero Memory means. Since this array controller (Smart Array P410i)  has no battry , so it`s cache is disabled by default (= Zero Memory). So this configuration is subjected to this warning which was written on Online ROM Flash Component for Windows - EG0300FBLSE (under Release Note):

  • Online firmware flashing of drives attached to an HP Smart Array controller running in Zero Memory (ZM) mode or an HP ProLiant host bus adapter (HBA) is NOT supported. Only offline firmware flashing of drives is supported for these configurations.

 I doen`t know how to update offline. my solution in theory is to enable the Controller Cache and try update firmware and after the update is taking place, I will disable it. do you think this is the solution?

 

HP Smart Array P440ar lockup error, server reboot. FW 6.60

$
0
0

HI guys,

for two months I have this error on my servers, DL380 G9.

  1. Option ROM POST Error: 1719-Slot 0 Drive Array - A controller failure event occurred prior to this power-up. (Previous lock up code = 0x12) Action: Install the latest controller firmware. If the problem persists, replace the controller.

  2. Option ROM POST Information: 1792-Slot 0 Drive Array - Valid Data Found in Write-Back Cache. Data will automatically be written to drive array. Action: No action required

the server freezes and then restarts, it does not show any errors in the /var/log/messages

we have already updated firmware, drivers S.O (hpsa), bios, we did not get a newer fw for the model disks (EG000300JWFUQ), for 15 servers we have 5 restart with the same error.

Server:

Manufacturer: HP
Product Name: ProLiant DL380 Gen9

FIRMWARE:

Firmware Name     Version   location

  • HP Ethernet 1Gb 4-port 331FLR Adapter 20.8.41 Embedded
  • HPE Ethernet 1Gb 4-port 331i Adapter - NIC 20.8.41 Embedded
  • HPE Smart Storage Battery 1 Firmware 2.1 Embedded
  • iLO 2.55 Aug 16 2017 System Board
  • Intelligent Platform Abstraction Data 25.13 System Board
  • Intelligent Provisioning 2.70.75
  • System Board Power Management Controller Firmware 1.0.9 System Board
  • Power Management Controller FW Bootloader 1.0 System Board
  • Redundant System ROM P89 v2.52 (10/25/2017) System Board
  • SAS Programmable Logic Device Version 0x03
  • System Board Server Platform Services (SPS) Firmware 3.1.3.21.0 System Board
  • Smart Array P440ar Controller 6.60 Embedded
  • System Programmable Logic Device Version 0x34 System Board
  • System ROM P89 v2.56 (01/22/2018) System Board

 

S.O:

LSB Version: :base-4.0-amd64:base-4.0-noarch:core-4.0-amd64:core-4.0-noarch
Distributor ID: RedHatEnterpriseServer
Description: Red Hat Enterprise Linux Server release 6.6 (Santiago)
Release: 6.6
Codename: Santiago

Driver:

filename: /lib/modules/2.6.32-573.7.1.el6.x86_64/weak-updates/hpsa/hpsa.ko
license: GPL
version: 3.4.18-108
description: Driver for HP Smart Array Controller version 3.4.18-108 (d186/s672)
author: Hewlett-Packard Company

DISK:

2 disk RAID 0+1 Interface Type: SAS
Size: 300 GB   Firmware Revision: HPD1   Model: HP EG000300JWFUQ

ANY IDEAS?

 Please help me.

Frank

Re: HPE ML10 GEN 9 SERVER

$
0
0

Hi,

Thank you for contacting us.

Please explain the issue.

1.What is the Windows OS?

2.Share snap shot, if you are getting any error message.

3.How are you installing OS?

4.What is RAID configured?

Let us know  above information for isolate the issue.

Regards,

 

Re: Hard Disk Firmware cannot get updated

$
0
0

Hi,

Offline means, booting from the Service Pack ProLiant DVD (.ISO).
So the new Drive Firmware is not in the Standard 7.1 DVD, but you can go to "SPP Custom Download" then chosse "SPP G7.1 + Supplements".
If go to the Eye than filter, it shows, that HPD8 is for EG0300FBLSE included.

This should work.

What is the Difference between "EG0300FCVBF" and "EG0300FBVFL" Hard Drives

$
0
0

Good Day Experts,

We have a mix of these Hard Drives in our HP Proliant DL380p Gen8 and wants to know exactly the difference between these two models. 

thank you in advance.

Re: Hard Disk Firmware cannot get updated

$
0
0

But when booting from "Service Pack ProLiant DVD", it still want to upgrade this firmware in next reboot. so what is offline?


Re: Proliant ML350p Gen8 suitable as workstation

$
0
0

Hi,

 

great thanks for the information. So will will refrain from buying the ML350p Gen8 and will go for the Z820

 

Thanks and best Regards

 

Re: HP ACU - No controllers detected (DL380 Gen9)?

$
0
0

Sir,

Is it possbile to manage from windows GUI, or do we need to reboot and login to inteligent provisioning? 

HPE ProLiant ML110 Gen10 + m.2 Samsung 970 EVO 2 TB

$
0
0

Is this compatible?

HPE ProLiant ML110 Gen10
ASUS HYPER M.2 X16 CARD (4x M.2 SSD)
m.2 Samsung 970 EVO 2 TB

I want to boot from usb key (ESXi) and SSD use as storage for virtual computers.

Thank You
Peter, IT admin of primary school

Re: What is the Difference between "EG0300FCVBF" and "EG0300FBVFL" Hard Drives

$
0
0

From your Customer Site there is no difference.

Same Specs, Part and SparePart Numbers, Warranty.

From HPE Site the Disks come from different Manufactur.

But HPE make them equal with there own Firmware and anything arround.

Re: Alternative SNMP insight monitoring ml350 gen10

$
0
0

Hi and thx for the reply

I have agentless Management Service and SNMP Service in automatical start.

I use the "Enablesma.bat" file in C:\programs\OEM\AMS\Service folder in admin.

I Have 4 servers in Gen 10 and it's work for 2 of them but fail for the others.

ssa (for raid controller) say "no controller detected"... I install the SPP (service proliant pack) in the last version but... it doesn't work.

I dont know if i must Configure the intelligent provisionning but if i can do it without restart the server, that would be cool