Hello,

Thank you for asking me.

You are a valuable customer. We are happy to support you.

This is the correct link or HPE site to download driver and firmware. Please follow the same site.

HPE ProLiant ML350p Gen8 Server

https://support.hpe.com/hpesc/public/km/product/5195931/Product?cc=us&lang=en#t=DriversandSoftware&sort=relevancy&layout=table&numberOfResults=25&f:@kmswtargetproductbaseenvironmentlatest=[5195931_Microsoft]

HPE ProLiant ML350p Gen8 Server.PNG

Please let me know if you have any queries.

If you feel this was helpful please click the KUDOS! thumb below

Regards,

 


unable to download iloamplifierpack

HPE MSA 2050 and Proliant BL 460C Gen8

$
0
0

Hi!

We have BladeSystem c7000 Enclosure G2 with: 2x HP 6G SAS BL Switch; Proliant BL460c Gen8 (Smart Array P721m) 

I was able to connect Volume HPE MSA 2050 to Proliant BL460c Gen9. But I could not connect Volume HPE MSA 2050 toProliant BL460c Gen8.

Are HPE MSA 2050 and Proliant BL 460C Gen8 compatible?

6G SAS Blade Switch fw:  4.3.6.0 ; MSA2050 FW: VL270P003-01 ; Smart Array P721m FW: 8.32 ; Smart Array P721m Driver: 106.26.0.6

 

 

Re: HPE MSA 2050 and Proliant BL 460C Gen8

Re: Port 84/85

$
0
0

Additional information:

According manual "HP ProLiant Gen8 Troubleshooting Guide" https://downloads.avaya.com/css/P8/documents/100175239 on the page 98 is a code 84 a just one part "major" and after switched pin S7 and S8 is code 85 a second part "minor".

 

System Maintenance Switch 8 System Maintenance Switch 7 POST LED display
OFF OFF Major Code
ON OFF Minor Code

DL380p Gen8 server with P420i controlleRAID 5 Expansion on P420i

$
0
0

DL380p Gen8 server with P420i controller 3x300GB RAID 5, we need to expand RAID 5  with 1 more HDD but SSA doesnot have manage data option. how to preform RAID Expantion ? kindly help.

Re: HpCISSs3 Error 5008, 129, 153 + Cissesrv 24607 = freezing VMs on node

$
0
0

Where is the VM located? Is it on the MSA2040?
What is the version of Windows running on the server?
How many VM's are running on Node A?
Are the Driver and Firmware versions of Network adapter, Storage controller same on both the Nodes?
If the issue is observed only when a VM is running on Node A, was it ever working fine on Node A? If it was working fine before, was there any changes made on Node A due to which the mentioned events started to be seen?
Has the VM configuration verified on Node A? Any difference when compared to Node B?

Please provide the source of the events that are observed on Node A. If possible share the System Event Log file. There are multiple reasons for the said events to be observed in the Event logs. Hence, we need to know the source of the events.

If there are any differences found in the driver, firmware or any other configuration between Node A & B, bring both Nodes to the same version or configuration.

For Event ID's 129 & 5008, please follow the solution provided in the below link. Perform the changes to the Power Management Settings as mentioned in the link below

https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=kc0135886en_us

After making the above changes, move a VM & monitor the server

Provide an update on the status

Thank you

Re: HP DL380 Gen9 Server Stop Code "NMI HARDWARE FAILURE"

$
0
0

Hello Sanjeev,

Thanks a lot for your quick reply.

Can i get details of this error & resolution corrected in newely released firmware as we have to submit the incident report to Client.

Thanks a lot for your support.


ProLiant DL360 Gen9 - can't get power limit to PCI slot

$
0
0

Hi,

we have few HPE servers but in this issue i have ProLiant DL360 Gen9 with RHEL 7.2 / 7.4

i run:

lspci -vvv |grep -i powerlimit

and get:


Slot #2, PowerLimit 0.000W; Interlock- NoCompl-
Slot #1, PowerLimit 0.000W; Interlock- NoCompl-
ExtTag- AttnBtn- AttnInd- PwrInd- RBE+ FLReset+ SlotPowerLimit 0.000W
ExtTag- AttnBtn- AttnInd- PwrInd- RBE+ FLReset+ SlotPowerLimit 0.000W
ExtTag- AttnBtn- AttnInd- PwrInd- RBE+ FLReset+ SlotPowerLimit 0.000W
ExtTag- AttnBtn- AttnInd- PwrInd- RBE+ FLReset+ SlotPowerLimit 0.000W
ExtTag+ AttnBtn- AttnInd- PwrInd- RBE+ FLReset- SlotPowerLimit 0.000W
ExtTag+ AttnBtn- AttnInd- PwrInd- RBE+ FLReset+ SlotPowerLimit 0.000W
Slot #3, PowerLimit 0.000W; Interlock- NoCompl-
ExtTag+ AttnBtn- AttnInd- PwrInd- RBE+ FLReset+ SlotPowerLimit 0.000W
ExtTag+ AttnBtn- AttnInd- PwrInd- RBE+ FLReset+ SlotPowerLimit 0.000W

 

i install SPP and update the packages and nothing is changed, it's happend only on HPE servers

 

can you please assist? 

Re: HpCISSs3 Error 5008, 129, 153 + Cissesrv 24607 = freezing VMs on node

$
0
0

Thank you for reply.

All VMs are on MSA2040
FW on controllers A/B, drivers (HBA) and SPP on nodes A/B are the same.
Win 2012 R2 Datacenter
Node A = 5VMs, Node B = 5 VMs
Issue appeard after updating SPP on None A (version 2017 from 2015)

What do you mean by "Has the VM configuration verified on Node A" ?

Event log: https://instruments.cz/wp-content/uploads/2020/02/event_log_node_a.zip
My own website link is secure.

I was messing with power options long time ago, no change for me running on power balance or high performance. Events 129 & 5008 still poping up. Just to clarify, Node B is running on balanced mode - no problems at all.

Thank you! Feel free to ask anything.
Jaromir

NCU link diagnostics

$
0
0

What would it be behind link test implemented within NCU. How is this tested in L1? I was running some tests and ended up with NIC port failing some of link tests and in the end the connection wend down all together.  

Re: Mismatch in OIDs of MIBs for DL380 Gen10

$
0
0

hello,

The testing consists of removing 1 power supply of the server, this is part of the acceptance of the server.

As the documentation establishes, the server will send .1.3.6.1.4.1.232.6069 (cpqHe4FltTolPowerSupplyACpowerloss), but instead the customer is receiving .1.3.6.1.5.232.0.6069. Due to this, the customer is not recognizing the OID because the MIBs shared are not correct.Wrong OID.png

According to cpqhlth MIB, the prefix is:

"The Compaq Enterprise number is 232.
-- The ASN.1 prefix to, and including the Compaq Enterprise is:
-- 1.3.6.1.4.1.232"

Is there a MIB file included with the additional cero (0) of the OID so the customer can recognized the alarm?

Advice about DL380 gen 10 disk options

$
0
0

I'm about to order a DL380 gen 10 server based on the 12 LFF chassis along with the optional 2 SFF rear disk box which I will use for a pair of 2.5" SSDs . With this combination, can I also I also fit two NVMes internally?

My requirement is for a server with 12 x 3.5" LFF HDDs and either 4 x SSDs or two SSDs plus two NVMes at the rear or internally. I would be grateful for any advice,

Andy

Hard Drive Swap

$
0
0

Hello,

Newby here. I am trying to install a new hard drive in 1 of 2 Raid 1 volumes I have in a DL360e.

I have been told that the hard drives have to match exactly or it could cause problems with my system and maybe erase the existing drive. 

One the front of the existing drive it says 10K, SAS 1.2 TB, 697631. I was told I need to match the 697631 or it would not work. I tried buying a hard drive online and received on that said almost the same thing but says 718292 and not 697631. Will this drive work or should I keep looking?

Thanks for you help.

 

Bob

Re: Compatible GPU for HP DL380p Gen8 Server

$
0
0

which gpu did you end up putting in?


I need the latest BIOS for the HP ML110 GEN9. Can I send it to my mailbox?

$
0
0

朋友给了一个主机上的HP ML110 GEN9的服务器主板,但是我下载最新的BIOS软体,提示我需要保修等合同,我并不具有那些。是否可以发送最新的BIOS软体到我的邮箱呢:859973256@qq.com   不甚感谢!WIN系统下更新的程式

Google Translated:

A friend gave a server motherboard of HP ML110 GEN9 on the host, but I downloaded the latest BIOS software, which prompted me to need a contract such as a warranty, and I did not have those. Is it possible to send the latest BIOS software to my mailbox: 859973256@qq.com Thank you very much! Updated programs under WIN system

Re: HpCISSs3 Error 5008, 129, 153 + Cissesrv 24607 = freezing VMs on node

$
0
0

Thank you for sharing the event log.

As per the event log, Events 129, 153 & 5008 are observed since 14th December 2019.

Please confirm if this is when the SPP was update on Node A?

Was the SPP updated only on Node A or was it also updated on Node B & Node B works fine even after SPP upgrade?

What was the exact version of SPP used, what was the exact version of SPP installed previously?

Below are the information that we find from the Event Logs:

Event ID 129: Source: HpCISSs3

The IO operation at logical block address 0x1d3edee00 for Disk 1 (PDO name: \Device\MPIODisk1) was retried.

Event ID 5008: Source: HpCISSs3

The description for Event ID 5008 from source HpCISSs3 cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local computer.

If the event originated on another computer, the display information had to be saved with the event.

Event ID: 153:  Source: disk

The IO operation at logical block address 0x1d3edee00 for Disk 1 (PDO name: \Device\MPIODisk1) was retried.

The Source indicates an issue with the Disk Drive & the Storage Driver.

You have mentioned the current storage Driver version on Node A: 106.26.0.64

We request to verify the storage driver version on Node B. If both server have different versions, we recommend to downgrade the driver version on Node A matching to the version on Node B. Once this is performed, monitor Node A to verify if the events are no more reported.

Find the download link for the Drivers, under Revision History Tab, you will find all the Driver versions that is required.

https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_90b6d3b309174d6f86065034ff#tab-history

Update us with the outcome of the above action plan

Thank you

Re: I need the latest BIOS for the HP ML110 GEN9. Can I send it to my mailbox?

$
0
0

Updated BIOS firmware file requires access to HPE Driver download page for which an HPE Passport Sign-in is required. Any server product is required to be registered under warranty or contract in the HPE Support agreement for downloading BIOS, iLO firmware & Service Pack for ProLiant files.

Please check with your friend if they have registered the server with HPE Support. If they have registered the product with HPE Support, they will be able to download the required firmware or driver files from the HPE Driver download page.

Thank you

SPP for HP DL380 G8

$
0
0

Dear all 

I want to install windows server 2016 on HP proliant DL380 G8.  Google said me befour the install windows server 2016 on G8 i need install HPE service pack than should be my server is support windows server2016

what SPP version i need to download for resole my issue ?

Thank you ! 

Re: Hard Drive Swap

$
0
0

We confirm that both the drives have the same specifications, no issues.

697631-001 1.2TB hot-plug SAS hard disk drive - 10,000 RPM, 6Gb/sec transfer rate, 2.5-inch small form factor (SFF), Enterprise, SmartDrive Carrier (SC)
718292-001 1.2TB hot-plug dual-port SAS hard disk drive - 6Gb/sec transfer rate, 10,000 RPM, 2.5-inch small form factor (SFF), Enterprise, SmartDrive Carrier (SC) - For use with Gen8/Gen9

However, about adding an additional drive in a RAID 1 Array, this is not correct. The RAID 1 Array would already have two drives, adding a 3rd drive is not possible unless you wanted to configure the 3rd drive as a spare.

We recommend to take a complete backup before you try anything, this will help restoring the Data in case of a Data loss.

RAID 1 Array support Even number of drives.

Please validate & proceed if supported.

Write back with more details about the current configuration for further clarifications.