Re: Power distribution on PSUs DL385 Gen10 Plus

$
0
0

Hello Pedae,

Thank you for posting your query.

As per the description, two servers have unusal Power distribution to Internal PSU's.

Could you please advise from where is this information captured? Are all these servers in your infrastructure connected to same Power Source?

Also please share the screenshots from iLO 5 GUI --> Power and Thermal 

a. Power Meter

b. Power

 

Please do check Integrated Management logs for any critical/Warning message? If any such alert is reported, please capture a screenshot?

 

Thank you

 

BR,

Aniket Chauhan

 


Re: Cache Module Status (Failed) on ProLiant DL380p Gen9 Server

Re: Power distribution on PSUs DL385 Gen10 Plus

$
0
0

Hello,

the information is from SNMP readings. All other Servers are ok but only two show this values. Here are the Screenshots

ILO_Power.jpgILO_Power01.jpgILO_Power02.jpg

Greetings Peter

Re: Power distribution on PSUs DL385 Gen10 Plus

$
0
0

These are the modes you can configure:

 

Balanced Mode—The system shares the power delivery equally between all installed power supplies.

High Efficiency Mode (Auto)—The system selects between the odd or even power supply based on a semirandomdistribution within a group of systems.

High Efficiency Mode (Odd Supply Standby)—The system places the odd power supply in standby.

High Efficiency Mode (Even Supply Standby)—The system places the even power supply in standby.

ML350 Gen 9 Issues with Additional Drive Cage/RAID

$
0
0

We have a customer site with ML350 Gen9 with all 8 SFF bays being used, so we have purchased a new  1 X HP Smart Array P440/4G , 1 X ML350 Gen 9 SFF Cage, and 2 x 872481-B21 1.8th SAS 10k Drives, every time we go into the Smart Array it says 'There are no configurable physical drives attache to the current Smart RAID/HBA Controller' We thought it could be the SAS cable so we have tried both part numbers 780991-001 & 774615-001 with no Joy. The Drives have power as they light up on power on to the server. Running out of ideas.

Re: HP Proliant DL380 G7 and G8 memory and ssd upgrade

$
0
0

can anyone help me?  i have a G7, i'm new to servers.  i want to take the 2.5hdds out and put in the 6 bay 3.5hdds to make my space at 24tbs, i can't find the cage i need (part number) or the riser card (part number) that i believe is needed.  thank you in advance.

Re: DL380 G7 Multiple Drive Cage - RAID Controller

$
0
0

i asked the below in a different post but maybe this is better suited here.

i have a G7, i'm new to servers.  i want to take the 2.5hdds out and put in the 6 bay 3.5hdds to max my space at 24tbs, i can't find the cage i need (part number) or the riser card (part number) that i believe is needed.  or maybe im just missing it all together and im looking for the wrong parts.  any help is appreciated.

HPE DL380 G7 drive cage

$
0
0

i am also looking to max out the storage on this 24tb, but need to convert he 2.5 to 3.5 bay, how do i do this?  in addition, once i fill the 24tb, can i hook another server directly to this in order to keep increasing my space, what is needed to do that?  any help is really appreciated.

 

P.S: Admin: Moved as a new topic from  


HPE Smart Array S100i SR Gen 10 Issues

$
0
0

Hello!

Ive recently purchased a Hp Proliant Dl380 Gen10 Installed a 2nd Processor. Installed VMware esxi got it all going. I went to configure the RAID setup and its not recognizing the 10K Hp SAS drives I have installed.

What ive checked so far.

- UEFI enabled in BIOS

- SMART Array Enabled 

- Drive board and cables secured

When i go into the Smart Array under Disk management im getting a warning 267 " There are no configurable physical drives attached to the current controller" . All the status lights on the drives are amber  "indicating failure". 

Is there anything else I can do to resolve this issue.

Thanks for any feedback

Re: Power distribution on PSUs DL385 Gen10 Plus

$
0
0

Hello Pedae,

Thank you for sharing the information.

From the screenshot both power supplies are working in Balanced Mode and the status of both PSUs is OK.

Do we notice any Critical/Warning messages in IML logs?

 

If yes,  I would suggest you to log a ticket with HPE Support Team for detailed analysis.

 

Thank you

 

BR,

Aniket Chauhan

 

 

Re: DL380 G7: possible to exchange SFF cage for LFF cage?

$
0
0

i want to say thank you for this thread.  this is exactly what i've been searching for.  i want to do the same conversion becaues its cheaper to run 6 x 4tb drives than to try and get the same storage w/ the 2.5 hdds.  in fact i couldnt find a higher sas drive other than 1tb and it was insanely priced.  i will be doing this for my upgrade to run this server.

Re: DL380 G7: possible to exchange SFF cage for LFF cage?

$
0
0

possible you can give a list of places where you bought the parts from?  i'd like to see how much i'm in for with this conversion, i can find some, but not all parts.

Re: Installation ILO firmware *.rpm files in Debian

$
0
0

Hi,

Did it work ? 

 

Regards,

Sudhir

Can we use M2 2280 nvme onboard for OS install, and whole disks array in raid mode for data store?

$
0
0

Hello Everyone

I have two HPE DL20 gen10 and planned to install the M2 2280 nvme ssd for OS install
the 6 SAS drives on one raid5 logical volume with HP H240 storage controller raid card  will be used for data storage only.
So the question is: Can we just normal install OS onto M2 SSD then going to disk management on windows server create a parition and use it ? and how the samsung 970 evo 500G nvme card compatibe ? i know there will be some issue with 3rd party part since the mis-report temp will cause of fan over 70%. But that not the end of the world since we just out the server in lab 

I'm new to HPE product and not expert on this subject, just buy and deploy for internal development, lab test  use only.

Thanks everyone

Re: HPE Smart Array S100i SR Gen 10 Issues

$
0
0

Hello,

You have to make sure which smart array controller you are using in this server or any other SA controller in the server.

Make sure backplane cable is connecting to S100i SR, only support SATA disk drive.

Please follow the HPE Smart Array S100i SR Gen10 Software RAID for more clarification.

https://h20195.www2.hpe.com/v2/getdocument.aspx?docname=a00019427enw

If you feel this was helpful please click the KUDOS! thumb below!   

Regards,

 


Re: HPE DL380 G7 drive cage

$
0
0

Hello,

You can follow the below hard disk cage.

Maximum Internal Storage for DL380 G7 server 

Hot Plug SFF SAS 19.2TB 16 x 1.2TB (with optional SFF drive cage)
Hot Plug LFF SATA 24.0TB 6 x 4TB (with optional LFF drive cage)
Hot Plug SFF SAS SSD 12.8TB 16 x 800GB (with optional SFF drive cage)
Hot Plug SFF SATA SSD 6.4TB 16 x 400GB (with optional SFF drive cage)
Hot Plug LFF SATA SSD 6.4TB 16 x 400GB (with optional SFF drive cage)

NOTE: Second drive cage installation replaces internal optical bay.
NOTE: Second drive cage requires the second controller or HP SAS Expander Card (468406-B21).

For HP Drive Cage Options, please refer DL380 G7 quickspecs link below: 

https://h20195.www2.hpe.com/v2/getdocument.aspx?docname=c04199811 

As well as you can also connect the below supported external HPE storage with this server.

HP Disk Storage Systems Disk Enclosures
HP D2600 Disk Enclosure AJ940A
HP D2700 Disk Enclosure AJ941A
NOTE: Please see the QuickSpecs for additional options and configuration information

If you feel this was helpful please click the KUDOS! thumb below!   

Regards,

Re: ML350 Gen 9 Issues with Additional Drive Cage/RAID

$
0
0

Hello

I would suggest you, check/update the SA controller firmware first.

Make sure system bios and SA controller firmware should be updated before adding the hard disk. 

If you feel this was helpful please click the KUDOS! thumb below!   

Regards,

Re: 64 GB RAM in HP DL380 G5

$
0
0

Hello,

I would suggest you follow the below steps.

1. Follow the memory configuration

https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c00752177

2. Power drain the server. ( remove power cables from the server and hold on the power switch for 30 Sec.)

3. Remove all add-on cards.

4. Check the server minimum configuration.

If you feel this was helpful please click the KUDOS! thumb below!   

Regards,

Re: HP PROLIANT DL180 GEN 9

$
0
0

Hello,

This is suspecting the system board issue but before that, you can try the as below steps.

1. Power drain the server. ( remove the power cable from the server and hold on power On switch for 30 Sec.)

2. Check the server with minimum configuration and remove all add-on cards.

HPE ProLiant DL180 Gen9 Server - Configuring Memory

https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c05239067

3. Update the server with the latest bios and firmware, if the server completes the POST or boot to OS.

4. Check the server with one by one processor with all the combinations of memories.

5. If the issue still persists, share the error message for further analysis.

If you feel this was helpful please click the KUDOS! thumb below!   

Regards,

 

Re: HPE ML150 G6-Noisy Fan

$
0
0

Hello,

I would suggest you try the below steps as well as make sure server bios and all firmware should be updated with the latest.

Press F9 at startup
1. Advanced Options

2. Thermal Configuration
3. Choose "increased cooling"

F10 to confirm.....Save & exit

Then

Press F9 at startup

1. Advanced Options
2. Thermal Configuration
3. Choose "Optimal cooling"

F10 to confirm.....Save & exit

If you feel this was helpful please click the KUDOS! thumb below!   