Re: DL380 G8 Power migration from 110v to 208v?

$
0
0

I don't see anything about mixing between circuit types.  I am expecting that could do this since they are auto sensing.  Just wondering if "walking" it over is ok to do, or if someone may have done it?


Re: Issue with ILO Self-Test error only when quad rank memories installed

$
0
0

Hi Suman

Thanks for your respond. Unfortunately update didn't solve the issue. I have also upgrade SSP and still nothing

Kind Regards

Slav

Re: DL360p Gen8 - ILO 4 "close" port 80

$
0
0

I've run across this same issue and was wondering if there was a solution to disable the non-SSL port setting. Also, if this can be set to something that disables the non-SSL port does that hamper the use of the iLO in any way?

Re: ProLiant ML110 Gen9 Performance

$
0
0

Chris27 This happen because the 3rs HD, don't have firmware HPE.

Try use equipment in Legacy Bios and Disable B140i controler (enable, ahci) in BIOS monde

LEGACY BIOS

From the System Utilities screen, select System Configuration → BIOS/Platform Configuration
(RBSU) → Boot Options → Boot Mode and press the Enter key.
2. Select a setting and press the Enter key:
o Legacy BIOS Mode—Configures the system to boot to a traditional operating system in Legacy
BIOS compatibility mode.

 

DISABLE B140I 

From the System Utilities screen, select System Configuration → BIOS/Platform Configuration
(RBSU) → System Options → SATA Controller Options → Embedded SATA Configuration →
Enable SATA AHCI Suppor, and then press the Enter key.

 

https://support.hpe.com/hpsc/doc/public/display?docId=c04441385

 

Re: HP Proliant DL360 gen9 with Smart Array P440ar Controller and 4x SSD in RAID 10 slow performance

$
0
0

Any update on what might cause this aside from "SmartPath" and caching on disk versus using the controller cache.

Thanks, GC

Red Hat 7 cannot recognize ethernet adapter on DL380P G8

$
0
0

Hello community, I have a Proliant HP DL380P with the following network adapters:

  • NetXtreme BCM5719 Gigabit Ethernet PCIe (Ethernet 1Gb 4-port 331FLR Adapter)
  • 82580 Gigabit Network Connection (NC365T 4-port Ethernet Server Adapter)

I installed Red Hat 7.2 but it recognizes only the NetXtreme adapter. Every cable/interface connected to the other adapter (82580) is not recognized by the OS. How can I solve this?

lspci show the following error:

04:00.0 Ethernet controller: Intel Corporation 82580 Gigabit Network Connection (rev 01)
        Subsystem: Hewlett-Packard Company NC365T 4-port Ethernet Server Adapter
        Physical Slot: 1
        Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr+ Stepping- SERR- FastB2B- DisINTx+
        Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx-
        Latency: 0, Cache Line Size: 64 bytes
        Interrupt: pin D routed to IRQ 52
        NUMA node: 0
        Region 0: Memory at f7f80000 (64-bit, non-prefetchable) [size=512K]
        Region 4: Memory at f7f70000 (64-bit, non-prefetchable) [size=16K]
        Capabilities: [40] Power Management version 3
                Flags: PMEClk- DSI+ D1- D2- AuxCurrent=0mA PME(D0+,D1-,D2-,D3hot+,D3cold+)
                Status: D0 NoSoftRst- PME-Enable- DSel=0 DScale=1 PME-
        Capabilities: [50] MSI: Enable- Count=1/1 Maskable+ 64bit+
                Address: 0000000000000000  Data: 0000
                Masking: 00000000  Pending: 00000000
        Capabilities: [70] MSI-X: Enable+ Count=10 Masked-
                Vector table: BAR=4 offset=00000000
                PBA: BAR=4 offset=00002000
        Capabilities: [a0] Express (v2) Endpoint, MSI 00
                DevCap: MaxPayload 512 bytes, PhantFunc 0, Latency L0s <512ns, L1 <64us
                        ExtTag- AttnBtn- AttnInd- PwrInd- RBE+ FLReset+ SlotPowerLimit 0.000W
                DevCtl: Report errors: Correctable+ Non-Fatal+ Fatal+ Unsupported+
                        RlxdOrd+ ExtTag- PhantFunc- AuxPwr- NoSnoop+ FLReset-
                        MaxPayload 256 bytes, MaxReadReq 4096 bytes
                DevSta: CorrErr+ UncorrErr- FatalErr- UnsuppReq+ AuxPwr+ TransPend-
                LnkCap: Port #0, Speed 5GT/s, Width x4, ASPM L0s L1, Exit Latency L0s <1us, L1 <8us
                        ClockPM- Surprise- LLActRep- BwNot- ASPMOptComp-
                LnkCtl: ASPM Disabled; RCB 64 bytes Disabled- CommClk+
                        ExtSynch- ClockPM- AutWidDis- BWInt- AutBWInt-
                LnkSta: Speed 5GT/s, Width x4, TrErr- Train- SlotClk+ DLActive- BWMgmt- ABWMgmt-
                DevCap2: Completion Timeout: Range ABCD, TimeoutDis+, LTR+, OBFF Not Supported
                DevCtl2: Completion Timeout: 50us to 50ms, TimeoutDis-, LTR-, OBFF Disabled
                LnkCtl2: Target Link Speed: 5GT/s, EnterCompliance- SpeedDis-
                         Transmit Margin: Normal Operating Range, EnterModifiedCompliance- ComplianceSOS-
                         Compliance De-emphasis: -6dB
                LnkSta2: Current De-emphasis Level: -6dB, EqualizationComplete-, EqualizationPhase1-
                         EqualizationPhase2-, EqualizationPhase3-, LinkEqualizationRequest-
        Capabilities: [e0] Vital Product Data
pcilib: sysfs_read_vpd: read failed: Input/output error
                Not readable
        Capabilities: [100 v1] Advanced Error Reporting
                UESta:  DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq+ ACSViol-
                UEMsk:  DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq+ ACSViol-
                UESvrt: DLP- SDES+ TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol-
                CESta:  RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr+
                CEMsk:  RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr-
                AERCap: First Error Pointer: 00, GenCap+ CGenEn- ChkCap+ ChkEn-
        Capabilities: [140 v1] Device Serial Number f4-ce-46-ff-ff-a8-a1-2f
        Capabilities: [1a0 v1] Transaction Processing Hints
                Device specific mode supported
                Steering table in TPH capability structure
        Capabilities: [1c0 v1] Latency Tolerance Reporting
                Max snoop latency: 0ns
                Max no snoop latency: 0ns
        Kernel driver in use: igb
        Kernel modules: igb

And here I copied the state of the single network device:

https://pastebin.com/frPnPff5

As you can see, NetXtreme works perfect, but no link at all for NC365T

Please help, thank you

Lucas

 

Re: Red Hat 7 cannot recognize ethernet adapter on DL380P G8

problem usehuc109060css600 SAS drive on HP DL380 G7 server

$
0
0

Hello,

I buy huc109060css600 600 GB SAS drive and I would like use this in DL380 G7 server.
DL380 G7 use P410i RAID controller - but this RAID controller dont found this huc109060css600 SAS drive.
How can I use this huc109060css600 SAS 600 GB drive with P410i RAID controller ?

Thank 
Jaro


Re: HP ML110 G10 and Monitoring/Alerts

Re: Issue with ILO Self-Test error only when quad rank memories installed

$
0
0

Hi,

May be its some other issue with server, request you to collect the diagnostic logs and log a case with HPE for further support.

https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-c03544302
https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-c03562462
https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-c03527443

Thank You!
I am a HPE employee
__________________________________________
Useful Links for ProLiant Servers and Community FAQ and Rules of Participation and Servers Blog.

Re: Updating Intelligent Provisioning over PXE

$
0
0

Hi

I have the same problem with IP 2.70b.

Also discovered that this problem occures while booting USB in legacy mode.

How can i boot IP from PXE and got ride of this "Error flashing NVRAM" message?

Re: problem usehuc109060css600 SAS drive on HP DL380 G7 server

Re: problem usehuc109060css600 SAS drive on HP DL380 G7 server

$
0
0

 wrote:

Hello,

I buy huc109060css600 600 GB SAS drive and I would like use this in DL380 G7 server.
DL380 G7 use P410i RAID controller - but this RAID controller dont found this huc109060css600 SAS drive.
How can I use this huc109060css600 SAS 600 GB drive with P410i RAID controller ?

Thank 
Jaro


can you provide more information?

You've installed the drive in the proper drive carrier?

When running the array configuration utility, the P410i doesn't see an unassigned drive?

Are you just installing the drive and expecting it to show as available in the OS? 

 

Replacing memory and BBWC on a Smart Array P410i

$
0
0

 

Hi,

We wan to replace the 256Mb memory cache module by a 512Mb memory cache module with a BBWC battery on a Smart Array P410i on a HP DL380 G6.

Here are the steps we will follow :

  1. Power off the server.
  2. Remove the 256Mb module.
  3. Install the 512Mb module.
  4. Add the BBWC battery.
  5. Power on the server.

Here are my questions :

  • Is there a risk of loosing RAID configuration during the operation (when removing the 256Mb module) ?
  • Is there anything to do before (or after) doing thoses actions (a backup of the server will be done before the operations) ?

Thanks for your answers.

Best regards,

Re: ProLiant DL380 G7 - Can't detect new SAS drives

$
0
0

Hi,
Try use the right tray for the G7. In the foto is tray for the G8  - this is not he same !

Regards
Jaro


Re: DL360 Gen9 Server Platform Services Firmware requires update

$
0
0

Short update. We updated the server with the spp2018.06 but nothing changed.

Re: ProLiant DL380 G7 - Can't detect new SAS drives

$
0
0

 wrote:

Are the drives definitely Gen specific and not (-/+)1 gen compatible? Other ones I've seen don't have that limitation. 

EDIT: HP after a few days have now told me that the drives are not supported for Gen7...they probably read your post! 


Not really a limitation of the drive itself, it is the carriers that are different

Re: HP PROLIANT HP system Management

$
0
0

hello  krasinka1409

thank you for your reply.

 

i tried to install the SNMP service is strated but still have the same issue.

please can you give me a link to install the webm drivers for this model??

i'm trying to install iLO Interface and Management Controller Driver.  i will reply  if it's working.

 

thank you :D

 

 

Re: Did ML150 G6 receive a microcode update?

Re: Red Hat 7 cannot recognize ethernet adapter on DL380P G8

Viewing all 30225 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>