HP ML350P-T08, Drive cage questions

Hello, whe have some ML350P T08 SFF servers. I have a few questions about the drive cage's in these servers. I have noticed that I can expand these servers with 2 drive cage's. At least there is room...

View Article


Re: ProLiant DL320e Gen8 v2 is noisy

Oh!, this is the DL320e Gen8 v1 not the v2 Let me go grab one.

View Article


Re: setting ILO remotely

This is a duplicate, please reply in the following topic:http://h30499.www3.hp.com/t5/ProLiant-Servers-ML-DL-SL/setting-ILO-remotely/m-p/6406838

View Article

Re: HP WBEM Provider

This is a duplicate, please reply in the following topic:http://h30499.www3.hp.com/t5/ITRC-HP-Systems-Insight-Manager/WBEM-Provider/m-p/6408152

View Article

Re: ProLiant DL320e Gen8 v2 is noisy

Ok, I got my DL320e Gen8 v1 up and running with one of those HD drives (couldn't find a second one) and my FANs are running at 19%.  The 05- HDD Max temperature reads 35ºC. Have you checked those SAS...

View Article


Re: Firmware Update issue

I think you're dealing with a bad NIC firmware update. See here for more discussion. Hopefully HP will put out an advisory and an official fix soon. 

View Article

Re: DL 180 G6 BMC firmware fault after HP Support pack online upgrade

hello HP support any update on this? same server with firmware updates done and the fans are going crazy!!! BMC error 106 on boot up... what's going on with this? a feedback will be much appreciated!!!

View Article

HP DL 360 G7

Working on a requirement and would like to know whether the below spec is still available in the market. Or is it getting End of Sale or End of Support. DL360G7 for Unix Server  -...

View Article


Re: ProLiant DL320e Gen8 v2 is noisy

Hi Oscar, The server was never opened, WE didnt replace anything so i dont think thats the cable's problem, As far as the hard disks, those temps were there since last year, It only started to make...

View Article


Re: HPSUM fails with "node inventory failed" error on ML310Gen8 V2 w/Win 2012...

Hi, you were right. I ran hpsum.bat logged as administrator (the real administrator account) and it ran perfectly. However, this being 2012 essentials, the administrator account was disabled, and I had...

View Article

Re: Intelligent Provisioning 1.60 breaks 2008 R2 install (will not accept...

One of my customers had this issue with 3 BL460c Gen8 servers. Thanks to your post I downgraded IP to 1.50 and got them up and running. Thanks for that!Do you think this issue will be fixed in another...

View Article

Best way to config storage for Server 2012 R2

Hi All,Have a DL380 G8 to test Server 2012 R2 on and looking for advise on how best to configure the hard disks for best performance and hopefully using some of the newer storage pool tech with...

View Article

Re: Smart Storage Administrator and Hyper-V 2012 R2 Core

I have exactly the same Problem. Hyper-V-2012R2 can access hpsmh, klick on HP Smart Storage Administrator, a new Windows Pops https://ServerNAME:2381/HPSSA/hpssainit.htm but it is blank. Testet IE 11...

View Article


Re: DL 180 G6 BMC firmware fault after HP Support pack online upgrade

Sorry for you. I had the same problem after firmware upgrade. "POST messages contain:BMC Version: NULLBMC xxxx Version: NULL (I can' remember what was xxxx)BMC not responding (there's it waiting for...

View Article

Not Ready Failures Reallocated Sectors in ADU report

Hi All, The server returns precheck by hpaducli Not Ready Failures for some disks. Also therea are strange results for Reallocated Sectors.hpaducli output in attachment. Please help to describe this...

View Article


Re: questions about AHCI and NCQ on smart array P400

I am  forced searching for the same answers,  the controller says my drives  support it and is enables on them,  but it disables them for my raid ,  How do i force it to enable on the controller...

View Article

Re: Smart Storage Administrator and Hyper-V 2012 R2 Core

In my case i installed new Windows server 2012 r2 Full, installed java and window https://ServerNAME:2381/HPSSA/hpssainit.htm    opened as necessary (From new Windows). Afterwards i installed IE 11 on...

View Article


HPSUM cp021548.exe - Error reading XML file

I'm using HPSUM to deploy HP Service Pack for ProLiant version 2014.02.0 on a ProLiant DL360 G5 running Server 2008 R2 SP1.  cp021548.exe, the  HP Broadcom Online Firmware Upgrade Utility for Windows...

View Article

Re: questions about AHCI and NCQ on smart array P400

Cyford wrote:I am  forced searching for the same answers,  the controller says my drives  support it and is enables on them,  but it disables them for my raid ,  How do i force it to enable on the...

View Article

Re: DL320 G4 (391657-421) with 2x 250GB SATA: what raid controller?

The embedded RAID controller is an Intel chipset software RAID controller and requires a special driver for the RAID functionality. The supported Smart Arrays for that system were the E200 and P400....