Event Id 129 - SOURCE= hpcisss2
I have an HP ProLiant ML 350 G5, which has an HP Smart Array E200i/128 BBWC Controller embedded. This controller manages two arrays (each with three 72 GB disks in RAID 5) This controller has...
View ArticleRe: HP SUM "Failed to add baseline" No default baseline found.
Exact same issue here as in your screenshot. Except this one's a G6...
View ArticleRe: HP Proliant DL380 G5 NIC's not found after firmware update
Same Problem with SPP 02.2014 and DL380G5.....
View Articlemove MS Exchage 2010 from one physical server to another
Hello,We have MS Exchange 2010 server running on a HP Proliant DL 380 G5, MFG SKU - 470064-552 (server 1).I have another HP Proliant DL 380 G5, MFG SKU - 459585-005 (server 2) which is slightly a...
View ArticleHPSUM 6.2.0 CLI bugs on Linux: no return codes, and /silent /romonly does not...
I am testing SPP 2014.02.0, which comes with the latest hpsum 6.2.0. I have noticed the following problems which prevent successful use of the CLI to script firmware update installation: 'hpsum...
View ArticleHP Proliant DL380 G4 server have no storage information
Hi All, For some reason our Proliant DL380 G4 servers are not displaying any storage information on the system management homepage. Our G3, G5, G7 and Gen8 servers are all fine, any idea why the G4s...
View ArticleRe: move MS Exchage 2010 from one physical server to another
Unfortunately not, once you destroy the array it no longer exists. Being the Exchange server I would apporach this very cautiously. Your best bet is to use something like Symantec Backup Exec System...
View ArticleRe: move MS Exchage 2010 from one physical server to another
Thanks, Good catch about the array
View ArticleGen8 NIC - missing buffer setting
I have a dl360p Gen8 server with the stock 331FLR adapter, running Windows Server 2008 R2. On older generations of servers/NICs, we changed a NIC setting called "Receive Buffers". This setting was...
View ArticleRe: New 1Gb Broadcom Multifunction Win64 driver (7.8.6.0) is buggy
Hi waaronb can you tell me if after install version 7.8.50 value of MTU was still 1500 or change ?In what exactly HP server and system this works ? Only Hyper-V Server 2012 ? Grettings
View ArticleRe: HPSUM cp021548.exe - Error reading XML file
Thanks, Suman. The HP Broadcom drivers are installed for the 2 NICs on this server. I used your link to download HP Broadcom Online Firmware Upgrade Utility for Windows Server x64 Editions...
View Articledl320e Gen8 V2 - Internal USB kit
Dear HP forum members, Where can we get the "HP USB Cable Kit"? (HP Gen8 FIO Internal USB Kit -- 662961-B21) I have a problem with our HP DL320e Gen8 V2 servers. We use a few maschines as cluster nodes...
View ArticleRe: New 1Gb Broadcom Multifunction Win64 driver (7.8.6.0) is buggy
The MTU was still 1500.The servers I have this running on now are a mix of DL360/DL380 for G5, G6 and G7.The Hyper-V machines in particular are DL360 G7 and DL380 G7 running Server 2012. The rest of...
View ArticleRe: move MS Exchage 2010 from one physical server to another
It would actually work (probably). I've moved sets of disks from one server to another without any issue, including moving a set of 8 disks from a DL380 G5 to a DL360 G6 (the drivers for a P400 and...
View ArticleRe: HP Proliant DL380 G4 server have no storage information
Is it the same whether you use WBEM or SNMP agent in the settings? I've sometimes seen a problem where WBEM wasn't showing as much info as the SNMP polling did. I'm not sure why, and it was only on...
View ArticleRe: Poor man's server redundancy?
The solutions to redundancy really depend on what kind of functions that server is performing.For example, if it's a file/print server, then it's pretty easy. If it's a database server, then there are...
View ArticleRe: Firmware Update issue
Ouch, that sounds like a nasty problem. I wonder if it's because it's updating the CCM when running unattended. I've installed the Broadcom firmware manually, and when it asked about the CCM I just...
View ArticleRe: Upgrade DL380 G6 with memory for max performance
For mirroring, I believe it mirrors channel 1 and 2, which must be populated exactly the same, and the 3rd channel has to be empty. For both CPUs. I think the config can be different between CPU 1 and...
View ArticleRe: Array Accelerator Battery has Failed
The server I'm having this problem with (a new DL380p Gen8) got rebooted yesterday for some maintenance, and the battery warning went away. I guess I'll see what happens when it's been 24 hours since...
View ArticleCan I suppress battery failed messages on servers with Drive Arrays?
I recently took over monitoring of our HP servers and the manager of the server group asked if I could suppress the battery failed messages since we don’t need the accelerator option of the array. If...
View Article