Internal Storage Controller Overheating ( Temperature Sensor 3 , Location...
I now have multiple ML350e Gen 8 Servers that are coming up with this error and a amber light on the front of the case ( amber light flashing on health light ) Tech support has had me upgrade frimware...
View ArticleRe: ML350 G6 can't see BBWC
The battery cable is definitely connected to the controller card. The only LED that seems to get lit on the battery pack is LED 1. It stays a steady green. None of the other lights seem to turn on....
View ArticleRe: Hardware RAID is disabled via NVRAM Controller setting
Hello.I have a same problem on my DL360G6 P410i controller.
View ArticleRe: HP Ml350e G8 Ram Upgrade Problem
Populate memory modules in the following order for each installed processor: 6-A4-B2-C5-D3-E1-F Smart Memory will be enabled only when all the installed memory modules are HP memory modules. Regards,...
View ArticleRe: HP System Management Homepage Blank
No luck as you can see...What can I have to ckech in advance?Thank you
View ArticleRe: Internal Storage Controller Overheating ( Temperature Sensor 3 , Location...
hi, Please be sure that you have the latest BIOS version....
View ArticleRe: HP Ml350e G8 Ram Upgrade Problem
hi, Can you paste here the product/spare number of the new dimms. thanks,
View ArticleRe: HP Ml350e G8 Ram Upgrade Problem
Im testing with some cheap Kingston brand KVR1333d3n9k2/8G 1333mhz ddr3 non ECC ram, will this work?
View ArticleRe: HP Ml350e G8 Ram Upgrade Problem
hi, Please try with hp labeled dimms, which are official supported acc. the quickpsecs of the server. thanks,
View ArticleRe: ML370 G4: Will Windows recognize data arrays after OS array is changed?
Hi, I am not sure if you have sorted this or not. The controller and the disks store the raid configuration. HTH Cheers Leon
View ArticleUpgrading from RAID1 to RAID5, possible?
Dear all, I manage a HP Proliant ML 350G6 running Windows Server 2008R2 with over a 79Gb RAID1 (2 * 79GB). Is it possible to move from the current Raid1 to a Raid5 without lossing any...
View ArticleWindows Server 2012 setup on a 6TB RAID 5 Partition?
HiI´d like to install Windows Server 2012 std. or Windows Server 2008 R2 on an DL380p Gen8 server with a RAID 5 partition (8 x 1TB disks).Windows creates one partition (in my case 100GB for System),...
View ArticleRe: Upgrading from RAID1 to RAID5, possible?
The answer is probably yes, if your current controller supports R5, it will only need the battery backed write cache to perform a raid / stripe migration. It does impact performance but it should be...
View ArticleRe: HP Proliant DL380 G5 update firmware for component: dg072abab3
hi, You can use the SPP to perform the offline update....
View ArticleRe: HP Proliant DL380 G5 update firmware for component: dg072abab3
Download the Firmware below, mount the iso through ilo (or burn it) boot from it, it should have a manual or auto process and you're done. If you're using esxi I would suggest you use the HP tunned...
View ArticleRe: Upgrading from RAID1 to RAID5, possible?
hi, Yes, you can. You can check the ACU User Guide (extend/expand array). You need to have BBWC/FBWC. Thanks regards,
View ArticleRe: Internal Storage Controller Overheating ( Temperature Sensor 3 , Location...
Both the ILO 4 and bios have been flashed with the same results as in amber lights on the front But Thank you
View ArticleRe: ML370 G4: Will Windows recognize data arrays after OS array is changed?
If you don't make a mistake and tell the Windows 2008 R2 installer to format the drives, your data should be safe. If your D: and E: drives are formatted as traditional "basic disks", there certainly...
View Article