Quantcast
Channel: All ProLiant Servers (ML,DL,SL) posts
Viewing all 30225 articles
Browse latest View live

Re: Disks to buy for DL380 G10 6230 sff


Re: 1611 FAN4 MISSING on DL380 G6

$
0
0

Did you fix it?
Same problem here with 5+6 in dual CPU system ... thus not booting anymore

Thanks.

Adot

Intelligent Provisioning - Install Windows Server Core on Micro SD

$
0
0

Hello together,

is there anybody who has installed a operating system on a Micro SD with intelligent provisioning on Gen10-Server?

We have here a ML350 G10, System ROM U41 v2.16, Smart Array P408i-a SR Gen10, intelligent provisioning 3.31.

iLo 5 (v1.46) shows microSD Flash Memory Card Present 29.90 GB, Intelligent provisioning - Operating System Installation - ask for Controller and Disk. There is noway to select HP SD Card as target.

Regards

 

 

HP ILO4 not able to connect

$
0
0

i have c7000 chassis where  i have 2 460C G9 server, From whih i able to connect the ILO4 and then Integrated remote console for server1.

But for another server2, I could connect  with the remote console of ilo4 without any problem,I connect to the remote console of ilo4 but in the java window after the word "connected", at the bottom left, after a few seconds I see the words "no video", and I can not interact with the system ,

Please suggest, can it be away after the server reboot,

Both server having same firmware: I36 07/15/2016

Re: DL380 Gen10 / Logical Drive Not Visible

$
0
0

As i do not know your expertise .. i have to ask this.

Did you initialize the drives through the windows disk management? (Set online - Format it etc)?

Re: Smart Array p408i-a Raid 6 adg replacement HP DL380 Gen10

$
0
0

Hi,

Thanks for your reply. there are 8 drives on the server that are under 1 logical drive. these failed drives are part of the logical drive.

MicroServer Gen 8 embedded SD failure

HP ILO4 not able to connect


DL-380 Gen 10 3 Fans always running at 94%Speed

$
0
0

After installing the Service Pack for ProLiant and update to the latest  BIOS (* RECOMMENDED * Online ROM Flash Component for Windows x64 - HPE ProLiant DL380 Gen10 (U30) Servers ),the fan 4,5,6 still run at almost full speed (94%) all the time  

Firmware Name Firmware Version Location

 

iLO 5 1.46 Jul 25 2019 System Board   System ROM U30 v2.20 (10/31/2019) System Board  

Intelligent Platform Abstraction Data 9.11.0 Build 39 System Board  

System Programmable Logic Device 0x2A System Board  

Power Management Controller Firmware 1.0.7 System Board  

Power Supply Firmware 1.00 Bay 1  

Innovation Engine (IE) Firmware 0.2.1.2 System Board  

Server Platform Services (SPS) Firmware 4.1.4.296 System Board  

Redundant System ROM U30 v2.10 (05/21/2019) System Board  

Intelligent Provisioning 3.20.154 System Board  

Power Management Controller FW Bootloader 1.1 System Board  

HPE Smart Storage Energy Pack 1 Firmware 0.60 Embedded Device  

HPE Ethernet 1Gb 4-port 331i Adapter - NIC 20.14.54 Embedded LOM  

HPE Smart Array P408i-a SR Gen10 1.99 Embedded RAID  

HP Ethernet 1Gb 4-port 331T Adapter 20.14.54 PCI-E Slot 1  

Embedded Video Controller 2.5 Embedded Device  

Drive HPG1 Embedded controller Port 1I Box 3 Bay 1  

Drive HPG1 Embedded controller Port 1I Box 3 Bay 2  

Drive HPG1 Embedded controller Port 2I Box 2 Bay 1  

Drive HPG1 Embedded controller Port 2I Box 2 Bay 2  

Drive HPG1 Embedded controller Port 2I Box 2 Bay 3  

Drive HPG1 Embedded controller Port 2I Box 2 Bay 4  

Fans   Fan Location Status Speed

Fan 1  System   OK 37% 

Fan 2  System   OK 56% 

Fan 3  System   OK 75% 

Fan 4  System   OK 94% 

Fan 5  System   OK 94% 

Fan 6  System   OK 94% 

 

Temperatures

23-BMC                 System  9  12   OK  57C  Caution: 110C; Critical: 115C 

25-HD Controller  System  8  8   OK  48C  Caution: 100C; Critical: N/A 

27-LOM                 System  7  14   OK  40C  Caution: 100C; Critical: N/A 

30-PCI 1            I/O Board  13  13   OK  40C  Caution: 100C; Critical: N/A 

56-P/S 1       Power Supply  1  13   OK  40C  Caution: N/A; Critical: N/A 

12-HD  Max            System  10  0   OK  35C  Caution: 60C; Critical: N/A 

24-BMC  Zone       System  9  14   OK  29C  Caution: 90C; Critical: 95C 

16-VR P1                System  11  1   OK  26C  Caution: 115C; Critical: 120C 

26-HD Cntlr Zone System  9  7   OK  25C  Caution: 85C; Critical: 90C 

53-Battery Zone   System  7  10   OK  25C  Caution: 75C; Critical: 80C 

29-LOM Card Zone  I/O Board  14  11   OK  24C  Caution: 75C; Critical: 80C 

31-PCI 1 Zone  I/O    Board  13  13   OK  24C  Caution: 75C; Critical: 80C 

33-PCI 2 Zone  I/O   Board  13  13   OK  24C  Caution: 75C; Critical: 80C 

35-PCI 3 Zone  I/O   Board  13  13   OK  24C  Caution: 75C; Critical: 80C

  14-Stor Batt 1        System  5  1   OK  23C  Caution: 60C; Critical: N/A 

15-Front Ambient  Ambient  10  1   OK  23C  Caution: 70C; Critical: N/A 

18-VR P1 Mem 1      System  13  1   OK  23C  Caution: 115C; Critical: 120C 

58-P/S 2 Zone  Power Supply  3  7   OK  23C  Caution: 75C; Critical: 80C 

19-VR P1 Mem 2        System  9  1   OK  22C  Caution: 115C; Critical: 120C 

01-Inlet Ambient     Ambient  15  0   OK  20C  Caution: 42C; Critical: 47C 

54-P/S 1 Inlet  Power Supply  1  10   OK  20C  Caution: N/A; Critical: N/A 

59-E-Fuse      Power Supply  4  9   OK  19C  Caution: 100C; Critical: N/A 

06-P1 DIMM 7-12  Memory  13  5   OK  0C  Caution: 90C; Critical: N/A 

While the tempeture still at below 60C I don't think there is a reson for the fan to run at such high speed.
Are there any thing that I can do to solve it? The fan has been run at 94% for a few days .

HPE iLO Integrated Remote Console - черный экран

$
0
0

Добрый день! Купили сервер ProLiant DL380p Gen8, активировали iLO 4 License Type - iLO Advanced
iLO Firmware Version - 2.61 Jul 27 2018 пароль был на корпусе сервера. При подключение через 
1. (.NET IRC)
2. (Java IRC)
Выдает черный экран, в чем ошибка?

Google Translation
Good afternoon! We bought the ProLiant DL380p Gen8 server, activated iLO 4 License Type - iLO Advanced
iLO Firmware Version - 2.61 Jul 27 2018 the password was on the server chassis. When connecting through

1. (.NET IRC)
2. (Java IRC)
Gives a black screen, what is the error?

DL360 G7 Win 2003 installation

$
0
0

Hello, as I wrote, I would like to install Windows 2003 on DL360 G7 but the installer says there is no HDD on my system.

I know I have to start the installer with some HP CD to configure the Smart Array,  but I dont have this CD. Is this softwase available on the HPE website? 

Can I get the link?

Peter 

Re: DL-380 Gen 10 3 Fans always running at 94%Speed

$
0
0

Hello,

Get the below changes done in RBSU:
System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options > Fan and Thermal Options >Thermal Configuration>Optimal Cooling

Check the status now.

If it is already set to "Optimal Cooling" change the cooling mode to "Increased Cooling." and check for issue resolution.


If still issue perist shutdown the server
Drain the flea power by disconnecting any power input, all the external cables (including Power and Network), external devices and pressing and holding down the power button for 10 seconds.
Check the fans and be sure the air flows over the drive.
Reseat the fans. Also reseat any PCI cards if connected.
Clear NVRAM

The following steps may be performed to clear NVRAM using the system maintenance switch on the system board:
a. Extend the server from the rack, remove the access panel, and locate the system maintenance switch (refer to item 1 in figure 1 below).
b. Move switch S6 from default 'Off' position to 'On', install the access panel and connect the power cable to the walljack and power it on.
c. When a message indicates that a maintenance switch has been turned on and the unit has been reset, power it off, remove the power cable from the walljack. Remove it from the rack,
remove the access panel and reverse switch S6 to 'Off' and then power the server back again.

Connect power cables again and see if the server behaves normal.
If still same issue reduce the server to minimum configuration.
Remove all external PCI cards attached to server.
Start adding parts in incremental manner to isolate the faulty component.

HP ProLiant DL380 Gen10 much more noise than ProLiant DL380 Gen9

$
0
0

Hi

I have a new HP DL380 Gen 10 server.

It makes much more noise (VERY noticable), than my DL380 Gen 9 server. Is this normal?

Thanks.

Re: hp ssd ex950 m.2 nvme on proliant ML30 G10

$
0
0

Greetings!

I believe you are checking the drive capacity under HPE Smart Storage Administrator. If not, please access the HPE Smart Storage Administrator and select the S100i controller. The M.2 drive should be visible there.

If the S100i controller doesn't show up in HPE Smart Storage Administrator or if you do not see the S100i identify during POST please access system configuration settings (F9) and enable the S100 controller.

Did you get a chance to check with compatible NVMe - M.2 - SSDs? Because the compatible ones are of lesser capacity then the one that you have been trying to install/test.

Please refer page# 23 on below link for more details:

https://h20195.www2.hpe.com/v2/getdocument.aspx?docname=a00053821enw 

 

Re: New Server ML110 GEN10, very slow video performance


Re: New Server ML110 GEN10, very slow video performance

$
0
0

 wrote:

Hello everyone.

I recently bought a Proliant ML110 GEN10, Xeon Bronze 3104 (1.70Ghz, Six Core), 16 GB ram.

The performance is very slow, I can't even play a YouTube video without looking slow. When I change windows from the operating system it also looks slow. I have the latest version of the HP Service Pack.

Has anyone happened to you? What can I do to fix it?


Might help others respond if you mention what OS you are using and the video resolution you are attempting to use 

Re: HP ProLiant DL380 Gen10 much more noise than ProLiant DL380 Gen9

$
0
0

Problem solved. I installed the latest BIOS update and now the fans are running at 11%.

Ordered a DL360 Gen10 with 4 x LFF Bays but have 2.5" drives.

$
0
0

Hi there, 

We incorrectly ordered a DL360 Gen10 with 4xLFF bays:  P03635-B21

Thinking it was an SFF form factor, we ordered:

3x:  872479-B21 1.2TB SAS 2.5" 

2x:  P04474-B21 480GB SSDs 2.5"

Is there a conversion kit or a way to modify the 4xLFF bay server to accomodate SFF drives? The server did not come with the drives pre-installed if that makes any difference. 

Thanks!

Re: DL380 Gen10 Uncorrectable PCI Express Error Detected. Slot """255""&qu

$
0
0

Hi,

Please see the recommendations below:

Update BIOS rom to latest - 2.22_11-13-2019(18 Nov 2019) (Please refer the rivision history for fixes), 

https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_55c6312f9c634f5782048519dd#tab-history

Recommended to change the workload profile to HPC-high performance computing or Virtulization Max performance. and check the status.

And for 

"PCI Bus Uncorrectable PCI Express Error Detected. Slot 255 (Segment 0x0, Bus 0x5D, Device 0x1, Function 0x0)"

"Bus 0x5D, Device 0x1, Function 0x0"==> Need to decode and check to which device its pointing.

Please try to to check PCI device properties or nvme drive properties incase its matching .

If identified, try to update the the firmware.

Regards,

Sudhir

Re: Intelligent Provisioning - Install Windows Server Core on Micro SD

$
0
0

Hi There,

Yes,  you will be able to install OS on a SD card in ML350 Gen10 server.

Please find the below snapshot for the your reference. 

Capture.JPG
 
Cheers
Iam a HPE employee
Viewing all 30225 articles
Browse latest View live