My HPE Proliant server Dl380 Gen 9 just Freeze/stuck.

$
0
0

I have a proliant server with the following specification:-

Dual processor (1) Intel xeon(r) CPU E5 2630 v4 with 2.20GHZ

                          (2) Intel xeon(r) CPU E5 2630 v4 with 1.80GHZ

RAM 32 GB (two RAMS each 16 GB on each processor).

HDD 8Terabyte ( 8 hdd installed each with 1TB in size)

PROBLEM:When i boot this server its boot but its get stuck/freeze sometimes before the POST boot is finishing and sometimes its freeze when i login into server.(Linux 18.0 LT).

Please anyone who can help me to solve this problem.

Thanks


Best, most compatible Win OS for Proliant G8 server?

$
0
0

I am getting a Proliant ML350p Gen 8 server for home use. It's a machine for learning server management/deployment and just having fun playing with high end gear. I will also use it for oddball things like running BOINC, gaming, and file/backup storage. 

I would like to know which version of Windows Server I should purchase for the easiest installation and most compatibility. Can I go with the latest and greatest, Windows Server 2019? Would I be better served (no pun intended) with something like Server 2016? 

Thanks!

 

Deploy Server using USB with Intelligent Provisioning

$
0
0

Hi,

I have a server HPE ProLiant DL320e Gen8 v2 with NVRAM error to read or reinstall Intelligent Provisioning, it is not a production server and it is out of HPE support contract. But I need to reinstall the Operating System (which is Linux) and I'm facing some errors due a missing RAID driver.

There is a way to boot the Intelligent Provisioning from a USB and iniatiate this installation this way? Like the old HP Smart Start?

Thanks

 

Re: DL380 Gen10 12LFF only sees 10 disks

$
0
0

Greetings!

By "2 drives on the bottom right", I understand that you are referring to slot 11 and 12

Page#74 https://h20195.www2.hpe.com/v2/GetDocument.aspx?docname=a00008180enw

I understand that you are using only SATA drives as S100i supports SATA drives only.

Please confirm by installing working drives on those slots.

Remove and reseat the cabling from the controller to the drive backplane.

Is the m.2 drive installed is an HPE drive? Please have the m.2 drive removed to check if there is any change in the behaviour.

Spare T15 screws fan Microserver Gen8

$
0
0

I'm looking for spare T15 screws (4) to mount the system fan of a  Microserver Gen8 to the chassis, but can't find the spare part number. I searched on partsurfer, looked in the maintenance manuals and searched on Google, but the only related spare is can find is the of the fan itself. Does anybody know if there is a spare part number for these screws or of any other way to obtain them? I think the G10 version uses the same screws.

Thanks,

Michiel

Re: Best, most compatible Win OS for Proliant G8 server?

$
0
0

Replying to myself as I think aloud.

The server has two E5-2640 V2 processors which gives me 12 physical cores. I'm sure one day I will want to max out the system and upgrade to something like the E5-2697 V2 which has has 12 physical cores per processor. Installing two of them will give me 24 cores. Wow-wee!

How would licensing and support work for that many cores? Don't the Server ediitions give you 16 core support standard and then an 8-core adder must be purchased? I'm wondering now if I would be better off going with a Pro or Enterprise edition of Windows 10 because they don't track processor and core counts.

Thoughts?

Need Advice on Expanding Storage on DL380 G7

$
0
0

Hello folks,

Could use some advice & verification before I spend the money and upgrade. Can you help?

WHAT I HAVE: DL380 G7, 8 discs, optical drive & a P410 controller upgraded with 512MB BBWC module.

WHAT I WANT: Upgrade to 16 discs.

WHAT I THINK I NEED TO DO:

  1. Remove the optical drive.
  2. Install 8 drive SFF drive cage (Part# 516914-B21)
  3. Install an additional P410 controller upgraded with 512MB BBWC module.
  4. Install 8 more SAS drives into the new bays.
  5. Access the RAID controller setup utility at boot up to create another couple of arrays (4 discs in each).

Overall, is this correct? If not where have I gone wrong? Assuming it's correct, is this a difficult process? Do you know of any documentation which tells you exactly how to do this? I'm more a software guy than hardware. If there's any way to connect the wrong cable to the wrong port and end up frying my DL380, I'll find it. I'm clever that way! I run a pair of 460W PSUs. Is that still sufficient going from 8 discs to 16? What about cooling? Anything I should be concerned about? I have a box fan aimed directly at the front of my DL380 and it seems happy enough with that plus normal home AC. 

I'm apprehensive because some cage listings talk about a back plane and cables, others don't. I just want to make sure I buy everything I need first time.

Finally, I originally bought my DL380 with the optical drive because I needed to load/install software from disc. I vaguely remember being told there's an alternative way to boot from/load software using a thumb drive connected to an internal USB. Is that correct?  

Thank you so much in advance for your help & expertise.

Can single-wide GPUs and double-wide GPUs be intermixed

$
0
0

Hi engineer

Sorry for the interruption. I haven't found any instructions on mixing single-width GPU and double-width GPU in many databases and forums. Hope to help answer,thanks.


Re: Can single-wide GPUs and double-wide GPUs be intermixed

$
0
0

Please provide information about the server on which the GPU's are installed.

Share the Model information about the server & the GPU's & share the information on which slot are the GPU's getting installed.

Thank you

Re: ML350 Gen9 P440 Expansion - Connection instrucrtions

$
0
0

Hi Arno,

 

As per the information shared if im correct you have a P440ar and a P440 controller. If this is the case then P440ar does not require a cable for the cache to be connected to the battery as this card has connections to the battery hardwired on the systemboard.

If you have purchased a P440 controller then this is a PCI based controller and for this a cable needs to be connected from the systemboard to the cache on the P440. Please check below link as it should be one of the two cables used:-

https://partsurfer.hpe.com/Search.aspx?SearchText=726821-B21

792836-001 or 792837-001

 

P440ar - Does not require additional power cable for the cache to receive backup power from battery.

P440 - Requires power cable for the cache to receive backup power from battery.

 

If the connections are good and still one of this shows failure but shows ok for the other then it means that bacttery is not the issue. Make sure that the firmware of the controller is updated so that it is not a reporting issue.

 

Hope this answers your query.

 

Cheers

Re: Write endurance on RAID 1 with two different size SSD

$
0
0

Thank you for reply.

Do I need to make any special setup to increase the endurance or just replace the old HDD with the new bigger one.

Re: Write endurance on RAID 1 with two different size SSD

$
0
0

If you replace a 120GB SSD with 200GB SSD in a RAID 1, only 120GB will be used.

The built-in controller of the SDD will ensure to use all the space and prevent hot-spots, however the usable space will be 120GB.

End of Support for ProLiant Series

$
0
0

I would like to know the End of Support dates for the following products:
ProLiant BL460c Gen8
ProLiant DL380p Gen8
ProLiant DL360 Gen8
ProLiant DL380 Gen9
ProLiant BL460c Gen9
ProLiant DL360 Gen9

Also, do you have a support page where I could check for the EOL/EOS details?

regards,
Jon

Re: DL360 G6 SAS Backplane firmware update failure: Read NVRAM - NVRAM_Data Failed Error Code is 82

$
0
0

Hello,

Good Day!!!

You can create a raid if the hard disk are showing in the SSA. ILO is reporting components.

Please share the components name (like SA controller name ) , which you updated the firmware as well as share the complete error code or IML error for more clarification.

Please let me know for further assistance.

If you feel this was helpful please click the KUDOS! thumb below!   

Regards,

 

 

 

Re: Best, most compatible Win OS for Proliant G8 server?


Re: DL360 G6 SAS Backplane firmware update failure: Read NVRAM - NVRAM_Data Failed Error Code is 82

Re: Deploy Server using USB with Intelligent Provisioning

$
0
0

Hello,

Please follow customer advisory.

Advisory: (Revision) HP ProLiant Gen8 and Gen9 Servers - How to Install/Reinstall Intelligent Provisioning (IP) if It Does Not Launch After Pressing F10 During Power-On Self-Test (POST)

https://support.hpe.com/hpesc/public/docDisplay?docId=c03693433

Intelligent Provisioning Recovery Media

https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a2b2caf8066e4a8b82a966d628#tab4

If the issue still persists use the latest SPP 8.1 for the Gen8 server. 

NOTE: Make sure you have the complete data backup before use SPP 8.1

Service Pack for ProLiant

https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a2b2caf8066e4a8b82a966d628#tab4

Please let us know for further assistance.

If you feel this was helpful please click the KUDOS! thumb below!   

Regards,

Sanjeev 

Re: DL380 G7 SAS HD LED Brightness Weirdness

$
0
0

OMG! I've only just seen your reply - years later. I'm so sorry for not responding sooner. Thanks for responding.

I must have got super busy and forgot to follow up. Anyway, here I am in Feb 2020. My DL380 G7 is still going strong, but still has the dim LED weirdness. I will look into this again now I have something to check.

Thanks again for responding. I hope you see this and know I (finally) appreciated your time.

All the best,

Sean.

Re: Video card not detected

$
0
0

Hi 

Per HPE ProLiant DL560 Gen8 QuickSpec there is no HPE Graphic Options available for HPE ProLiant DL560 Gen8 server.

https://h20195.www2.hpe.com/v2/GetDocument.aspx?docname=c04123206

Even as per HP ProLiant DL560 Gen8 Server - Spare Parts and  Option Parts list there is no HPE Graphic card available for this model.

HP ProLiant DL560 Gen8 Server - Spare Parts

https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c03460139

HPE ProLiant DL560 Gen8 Server Series - Option Parts

https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c03453797#N10BAE

 

However if still you want to use graphic card, you can try HPE supported Graphic card available for DL580 Gen8 server.

HPE ProLiant DL580 Gen8 QuickSpec.

https://h20195.www2.hpe.com/v2/getdocument.aspx?docname=c04199329

Re: HPE DL380 Gen9 and nVidia M4000 GPU

$
0
0

Hi I write to you from HP support.

I have same server DL380 GEN9 and nvidia m4000.

Do you resolve you problem? Which cable do you use (10pin to 6pin)?
Do you try this gpu on Ubuntu?

Viewing all 30225 articles