Hi,
Now, We know following:
1. Embedded controller P410i detected but no physical drives seen in it.
2. There is a 512Mb cache module but not configured, since there is no logical drive detected.
But you mentioned about 4 drives seen in the ILO.
Which means drives are present but controller is unable to communicate with them.
I have a feeling that drives are configured earlier in Raid 6 which required license.
Can you please confirm, if yes can
RAID Support RAID 6, 6+0 (Advanced Data Guarding)
NOTE: RAID 6, 6+0 can be enabled with one of the following combinations:
256 MB cache, Battery kit and Smart Array Advanced Pack License key
option upgrades
512 MB BBWC/FBWC and Smart Array Advanced Pack License key option
upgrades
1G FBWC and Smart Array Advanced Pack License key option upgrades
Refer following link to know about HP Smart Array Advanced Pack (SAAP 2.0)
http://www.ikt-handel.no/pdf/848CDB9D-54ED-4107-9A12-0B0021EC3C9E.pdf
https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c03245319
Follow the steps below to add SAAP2.0 license key if you have:
HP ProLiant Servers - HP Smart Array Advanced Pack (SAAP): Installing a License Key with Option ROM Configuration for Arrays (ORCA)
https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c02793105
or
To install a License Key in ACU:
- Open ACU and click the Configuration tab.
- Select a controller from the Controller/Device menu.
- In the Available Tasks panel, click Manage License Keys.
- Click Add License Key.
- Enter License Key number.
- Click Save
Reboot and check if logical drive detected.
Enter into ACU utility again and verify whether cache is configured if not, configure is now for the logical drive.
Incase you dont have license key and want to proceed without that then use HP Drive Erase in ACU and then reconfigure different Raid (0/1/5)
If you feel this was helpful please click the KUDOS! thumb below!
Regards,
Sudhir