Hello,
I have a DL360p gen8 server.
- in bay 1 to 4 I got 4 HP SAS drives EG000300JWSJP with latest firmware HPD2, drives are installed in their original caddies P/N 651687-001, array is RAID5 and working fine.
- In bay 5 and 6 I have two Crucial MX500 SSD drives in HP original caddies, same PN as the other ones, array is RAID1 and working fine.
- The controller is the embedded one, P420i with 2GB FBWC module and battery.
At startup all drives are flashing their led and everyhing is lit normally (blue ID led, activity ring, warning led, and disk green/amber led).
After the LED check the indicators of the crucial drives are working as expected, central green icon lit, activity ring when used, blue id indicator is on when requested and if i remove a drive from array the warning indicators lights up
For the HP drives the only indicator working is the activity ring, no green disk indicator, no blue light if identification is requested, and no warning light if I remove a disk from the array.
Any idea of what it could cause the problem??