Hi Frankie,
How do you add drive on ML350 Gen9 Server ?
I'm also have the same problems run latest HP SPP also didnt found way to add disk on existing raid 5.
Can you provide the link again seems the link earlier is unreachable ?
Thanks.
Hi Frankie,
How do you add drive on ML350 Gen9 Server ?
I'm also have the same problems run latest HP SPP also didnt found way to add disk on existing raid 5.
Can you provide the link again seems the link earlier is unreachable ?
Thanks.
Are the above-mentioned SSDs compatible with HP DL380 Gen8 servers??
Thank you, Tom
I'm trying to discover and understand what options exist for HP DL380 Gen8 servers to install vSphere on USB media or flash cards or what.
I've been told about HP 32 GB flash cards but not whether two of them can be installed in RAID1, I know there's the 8 GB dual microSD USB devices, but not whether these can be used in a Gen8 server...I would also like to know if the RAID1 USB device can be used with non-HPE microSD cards, which would be cheaper...
Thank you, Tom
Hi there, I have an HP ProLiant DL360p Gen8 running Ubuntu server. It has two hot swap SAS HDDs in RAID 1. One of those HDDs has the flashing status light amber & green, which from what I can find online means the HDD is predicted to fail. I have a replacement HDD, but not sure what steps are involved to swap it out to rebuild the array with the new HDD.
On the Dell and Lenovo servers I have worked on, there is typically a setting in the RAID utility to mark the failing drive as offline. Once the RAID controller sees it as offline, then I can pop it out, plug in the new one, and the array starts rebuilding automatically. I was in the RAID utility for this server but I couldn't find any such option to make the failing HDD offline. I inserted the new HDD into the server (in one of the spare bays) which the RAID utility sees, but as unconfigured. I couldn't find any option to get it to start rebuilding the array. So the array remains degraded.
Also, is there some way of doing this through the iLO? I'd prefer to avoid having to restart the server and accessing the RAID utility that way if possible. The iLO shows the status of the array but as far as I can tell, doesn't provide any option.
Thanks in advance!
Can one use more than one (1) SD card in Gen8 servers??
If so, would they function as a RAID 1??
Thank you, Tom
Hi new user here,
I'm supporting a DL380 Gen 9 and am getting an SSD Wearout error from iLO. This server is configured with the P440 raid controller. Now I need to take down the server to replace the Raid cache battery since it's also bad, is there any special procedure to replace the SSD cache drive, or do I just swap it out?
Thank you, I was afraid you would say that. :)
I will get some good SanDisk flash cards. :)
Thank you, Tom
Thank you, I read this, it is a good find and hopefully it helps others too.
Thank you, Tom
If HP is unable to patch, opts not to patch or is waiting on updates from Intel this needs to be listed in the CUSTOMER BULLETIN.
Thanks for that, I found the .bin files.
There are two zip files, each containing a bin file:
cp034104.zip contains IEGen10_0.1.5.2.signed.bin
cp034105.zip contains IEGen10_0.1.5.2b.signed.bin
Is one of them an incremental update perhaps?
We just ran it from the ESXi CLI (the .vmexe file) and it worked fine.
Hello, we updated three DL360 Gen9 with latest 2.54 BIOS. Now Intel and HP say this BIOS (microcode) is buggy. How can we revert to 2.52? We cannot get it since BIOS 2.52 is not available for free download while 2.54 was.
I can find a RPM and a EXE version of this bundle, but not the BIN.
So there is no B version for the two.
But usually if there is a B version, they changed something regarding the firmware loader, but the firmware itself remains the same.
Hi,
Im use a ProLiant DL560 Gen8 (out of warrenty) with a Fusion-io HP 2410GB MLC PCIe ioDrive2 Duo for ProLiant Servers, port 1, ioDrive 1200GB. Since a few Weeks i have follow error in the logs:
Do you have any Idea how i can repair/fix this ?